A
Anonymous Posted on Mar 03, 2015

How many watts is in a 15amp braker - Heating & Cooling

1 Answer

Jerry Z

Level 2:

An expert who has achieved level 2 by getting 100 points

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Sergeant:

An expert that has over 500 points.

  • Expert 180 Answers
  • Posted on Mar 03, 2015
Jerry Z
Expert
Level 2:

An expert who has achieved level 2 by getting 100 points

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Sergeant:

An expert that has over 500 points.

Joined: Feb 11, 2013
Answers
180
Questions
0
Helped
60417
Points
537

Watts = volts X amps. So if you're on a normal household 120v circuit, watts = 120 X 15. A single 15 amp socket should handle an appliance up to about 600 watts.

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
2answers

I have a problem with an Alinco-135 UK blowing inline fuses when I connect to a battery.fuses

10meter radio transcievers
Alinco DR-135UK 25.000-29.90 MHz (programmable) - needs ALINCO ERW-10.Ham radio? 0-25 Watt USB/LSB (variable)
not transmitting it blows fuse. right>?
bad caps inside shorted too cause
or bad DC power regulator )
assumes using right sized fuse. answers.
it does need service,
if blows only TX mode, antenna good.
the fuse needs more amps to TX 25times more
12amp min, 15amp fuse or 20.
one model said 15amp fuse. DR135, books on UK version not easy to find ask maker , they have vast manuals I see

http://www.alinco.com/pdffiles/
0helpful
1answer

Step up convertor

VT 2300F Step Up Down Transformer with American Grounded Plug 2300 Watts

The wattage rating for the router is just under 2000 watts. You'll want a converter with a wattage rating more than the rating of the router.
VT3000 Step Up Down Voltage Transformer 3000 Watts
I would personally go for the 3000 watt converter.
0helpful
1answer

Is a house plug with a cfic braker light suppose to be red or green

Most are green when functioning properly. Many have no lights at all. Try depressing the reset and see if the outlet works again. If not there are other things to look for. Often times one GFI outlet feeds multiple more outlets from the "load" connection on the back side of the GFI. If there is something wet, overloading the rating, or something with a fault in any of the outlets multipled off the single GFI it will trip. Disconnect all devices then attempt to reset. If that doesn't work and you possess some electrical skills pull the GFI outlet and disconnect the wires going to the "load" connection (While power is off) Re-energize and attempt to reset the GFI Outlet. If it resets your problem is beyond that outlet in the circuit of what you disconnect. You may not have found all the affected outlets. FYI if you have a 15amp GFI the rule of thumb is you can put more devices on outlets working off or through the GFI that add up to more than 1500 watts. If it is a 20amp GFI a quick rule of thumb is no load over 2000 watts. Space heaters, blow dryers, and hair curlers are often 1800 watts each. One alone and can trip a 15 amp GFI.
0helpful
1answer

15amp 1000watt dimmer gets extremely hot with 960 watt load

Electricians use the 80% rule.
When watt rating is 1000, we say 800 watts maximum. Same for wire ratings, and circuit breaker ratings, switch ratings, etc. 80% rule is the rule for electricians.
The closer you run a device at full load, the warmer it gets and the more quickly the device fails.
The signal that a dimmer is failing is heat.
I suggest replacing 1000watt dimmer with 1500watt dimmer, or reducing load.
All dimmers get warm, but should not be hot. 1500watt dimmers usually have aluminum fins on the face to dissipate heat. So 1500watt dimmers look different than 1000watt dimmers.
If you reduce load, and 1000watt dimmer still gets hot with reduced load, then dimmer has gone bad.
0helpful
1answer

I have a audition 150 watts x 2ch bridgeable high power amp serial # 00400274 need size of inline fuse. does not show size of fuse on diagram

hi.

if it is 150 watts TOTAL power then you should use a 15 amp fuse.
(150w / 12v = 12.5amps, 15amp fuse should provide the correct protection.)

if the system is 150 watts PER CHANNEL. then it will be 300 watts total and a 30 amp fuse should be used.
(300w / 12v = 25 amps. 30amp fuse should be used.)

30 amp is normally the highest fuse recommended for an car audio system, so i would not use higher than this without taking the unit to a qualified auto electrician, to get the system checked for safety. if you have any further questions please feel free to ask.
0helpful
1answer

Inead a new timer for a jacuzzi

Normal 0 false false false MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-parent:""; mso-padding-alt:0in 5.4pt 0in 5.4pt; mso-para-margin:0in; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:10.0pt; font-family:"Times New Roman"; mso-ansi-language:#0400; mso-fareast-language:#0400; mso-bidi-language:#0400;} First thing:
Determine Hp (horsepower), wattage and volts. There is a label that shows these values

1) Indoor Jacuzzi pumps are usually 115Volt and 1 Hp to 1.5 Hp. 1 Hp or horsepower is 746 Watt, 1.5 Hp is 1119 Watts
.
Normal 0 false false false MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-parent:""; mso-padding-alt:0in 5.4pt 0in 5.4pt; mso-para-margin:0in; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:10.0pt; font-family:"Times New Roman"; mso-ansi-language:#0400; mso-fareast-language:#0400; mso-bidi-language:#0400;} Which timer? If wiring is already connected to a switch, ordinary in-wall 15Amp timer can handle up to 1400 Watts.

Normal 0 false false false MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-parent:""; mso-padding-alt:0in 5.4pt 0in 5.4pt; mso-para-margin:0in; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:10.0pt; font-family:"Times New Roman"; mso-ansi-language:#0400; mso-fareast-language:#0400; mso-bidi-language:#0400;} 2) Outdoor Jacuzzi or Hot Tub pumps can be 115Volt or 240Volt and up to 5 Hp. 5 Hp is 3730 Watts

Normal 0 false false false MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-parent:""; mso-padding-alt:0in 5.4pt 0in 5.4pt; mso-para-margin:0in; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:10.0pt; font-family:"Times New Roman"; mso-ansi-language:#0400; mso-fareast-language:#0400; mso-bidi-language:#0400;}

Which timer?: Wide variety of Pool and spa controls at Aplus
Normal 0 false false false MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-parent:""; mso-padding-alt:0in 5.4pt 0in 5.4pt; mso-para-margin:0in; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:10.0pt; font-family:"Times New Roman"; mso-ansi-language:#0400; mso-fareast-language:#0400; mso-bidi-language:#0400;} http://www.aplussupply.com/intermatic/timerpool.htm

If you need more help, re-post electrical details about your jacuzzi and exactly what you want timer to do.

1helpful
1answer

My europower ep2500 amp the braker trips when I power it on

Hi,circiut braker trips only when the load on it is to much.
That is carry what is bigger than it watt, or can not carry too well. If you have another amp., you can put some load on that to reduce to braker always tripping off.

If that is the only amp. you have in what you are doing, just reduce the amp. volume to half(setting at 12 O CLOCK). it will work, but will not be too loud as before.

Take care.
0helpful
1answer

240v/750watt heater on 20amp

Yes, a 20-amp, double pole breaker will easily support that heater.

The calculation:

Watts = Volts x Amps

750 watts = 240 volts * x

x = 3.1 Amps


Charlie
0helpful
1answer

Marley B2451 wall heater

These are only 1500 watt heaters.

They 'could' heat a 20 x 20 foot room (with good, tight construction), with a slow temperture rise.


Check the company web site at http://www.qmarkmeh.com/

Doug
Not finding what you are looking for?

69 views

Ask a Question

Usually answered in minutes!

Top Heating & Cooling Experts

Paul Carew

Level 3 Expert

3808 Answers

john h

Level 3 Expert

29494 Answers

Brad Brown

Level 3 Expert

19187 Answers

Are you a Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides