Anonymous Posted on Aug 19, 2014

Whats wrong when rv a/c fan comes on but not compresser

Just installed new top unit, only the blower comes on not the compresser to blow cold air

1 Answer

Matt

Level 1:

An expert who has achieved level 1.

MVP:

An expert that got 5 achievements.

New Friend:

An expert that has 1 follower.

Hot-Shot:

An expert who has answered 20 questions.

  • Contributor 52 Answers
  • Posted on Aug 19, 2014
Matt
Contributor
Level 1:

An expert who has achieved level 1.

MVP:

An expert that got 5 achievements.

New Friend:

An expert that has 1 follower.

Hot-Shot:

An expert who has answered 20 questions.

Joined: Oct 03, 2012
Answers
52
Questions
0
Helped
24710
Points
90

5 Related Answers

pierre1811

Perry Putnam

  • 144 Answers
  • Posted on Mar 24, 2009

SOURCE: unit blows cold but freezes up

You are low on refrigerant.

Ad

Anonymous

  • 4 Answers
  • Posted on May 19, 2009

SOURCE: carrier air-v AC is not blowing cold air

There could be a freon leak, or just low freon levels. If this is the case, you have to call a certified a/c technician to recharge your system.

Anonymous

  • 6 Answers
  • Posted on Jun 01, 2009

SOURCE: compresser is not running

The condenser fan motor is most likely blown. A replacement fan motor and a run capacitor are most likely needed to get it back in working order.

Anonymous

  • 17 Answers
  • Posted on Jun 06, 2009

SOURCE: Recycling to soon?

sounds like the unit is low on freon. it will need to be serviced so the leak can be fixed then recharged.

Anonymous

  • 38 Answers
  • Posted on Jul 01, 2009

SOURCE: lennox air unit not blowing cold air

your fan motor outside is going bad, have a service company change it out for you.

the motor stopped working and that overheated the compressor shutting it down on thermal cutout, and it will only come on once it cools down

Ad

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer

Fan run compressor run but no cold air

DuoTherm by Domestic-Fan runs, no cold air - iRV2 Forums

www.irv2.com > ... > RV Systems & Appliances
Jan 22, 2012 - 12 posts - ‎4 authors Duo Therm by Dometic 13500 BTU air conditioning with ducting, furnace. I. ... If the fan runs but no cold air and the compressor feels like it is ...

A/C just stopped blowing cold.....any ideas??! - RV Forum

www.rvforum.net > ... > RVing message boards > Trailers & Fifthwheels
Jul 27, 2008 - 23 posts - ‎6 authors We have run it continuos like this before without any troubles. Thanks for the help! ....When you switch the AC unit on, the fan runs, but the compressor doesnt fire up. You used to be able ... You can find Dometic here. Logged. Dometic Duo Them Air Conditioner Cycles
4 posts
Jul 21, 2015
Dometic SL-135 A/C problem
7 posts
May 29, 2012
Dometic ac compressor runs but fan does not on auto
6 posts
Jun 5, 2011
AC blower runs full time w/ AC on
14 posts
Sep 2, 2009
More results from www.rvforum.net
0helpful
1answer

I have recently replaced the fan motor on my Briskair roof top A/C unit, should the squirrel cage draw air from inside the trailer and blow out rear of the unit, or have I installed this fan incorrectly?

Yes the air should be drawn from the trailer, over the cold coils and then
back into the trailer, whether rear or front.
The condenser coils should be self contained on top and blow
warm air outside the trailer

If this was helpful please rate me.
Leo Ponder Appliance-Tyler,Texas
[email protected]
0helpful
1answer

I have a central heating and air unit. The unit

sunds like the fan bearings have seized up or u have a bad fan capacitor take a screwdriver and spin ith blade to where the air would be coming out the top and if it startswhen u spin it u need a fan capacitor
0helpful
1answer

Duo Therm 13.5K Won't blow cold air?

needs freon. valve must be installed on unit in order to charge. if you know nothig about freon, call a repairman. Check craigslist.com
1helpful
1answer
0helpful
1answer

WHEN THE HEATER COMES ON THE FAN STARTS INSTANTLY AND BLOWS COLD

Do you have a heat pump? If so this is normal. You are probably used to a gas furnace. There are heat pumps that do have a delay though. Look on the circuit board in the air handler. There may be a set of pins that say 0-30-60-90 yours may be at 0. Also some digital T-stats offer that function for delay off to get the extra heat or cold from the system. Find out what the model number of the air handler and call the Goodman supplier in your area to see if you have these options.
If you have a gas furnace and it's not delaying the blower there is definately something wrong.
0helpful
1answer

No Cold Air

Have you removed inside filters and cleaned them? have you gone up and removed the cover to see if fins are dirty, or perhaps wasps etc. Does fan only have one speed on thermostat. Does fan run faster on fan only operation? Is it tripping your breaker at all?
Not finding what you are looking for?

51 views

Ask a Question

Usually answered in minutes!

Top Heating & Cooling Experts

Paul Carew

Level 3 Expert

3808 Answers

john h

Level 3 Expert

29494 Answers

Brad Brown

Level 3 Expert

19187 Answers

Are you a Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...