...amperage.It should be under 14-16 Amps. 8.If its half of the value or nothing comes then. 9 half value means(one magnetron is working 10. No value means F3 fuse blown and check the cause why it ...
...amperage.It should be under 14-16 Amps. 8.If its half of the value or nothing comes then. 9 half value means(one magnetron is working 10. No value means F3 fuse blown and check the cause why it ...
...4. Press and hold the MGTRON soft key on the keypad to energize the magnetrons. 5. Observe the amperage on the meter. Typical readings are: NORTH AMERICA: 12-14 amps at 240VAC/13-16 amps at ...
...4. Press and hold the MGTRON soft key on the keypad to energize the magnetrons. 5. Observe the amperage on the meter. Typical readings are: NORTH AMERICA: 12-14 amps at 240VAC/13-16 amps at ...
...4. Press and hold the MGTRON soft key on the keypad to energize the magnetrons. 5. Observe the amperage on the meter. Typical readings are: NORTH AMERICA: 12-14 amps at 240VAC/13-16 amps at ...
...opened,to save the electronics it should be on or near the board replace it with the right size/amperage fuse its critical, before doing so do a check of all wires and anything else that looks ...
221 questions posted
Usually answered in minutes!
30 Questions
1 Questions