Check the Door connections.
Tests/Procedures:
1. Access and inspect the right power sliding door contact switch for contamination, alignment and/or damaged terminals of the contact and address it as needed.
2. Check the circuits of the right sliding door contact switch on the door side of the contact for a potential open or short running between the contact switch and detent switch connections and address the circuits as needed.
3. Check the signal of the detent switch with an ohmmeter by measuring resistance between the contact terminals 1 and 3 on the door side of the sliding contact switch. When thedoor handle is operated, the ohmmeter should indicating momentary continuity. The door handle should only need to be moved in 10 degree increments to the value of the detent switch to change.