Zanussi Dryers - Recent Questions, Troubleshooting & Support

0helpful
1answer

Hi I have a Zanussi Condenser dryer mod no.ZDC46130W

Clean the air intake grill t the rear left corner. https://www.manualslib.com/manual/198228/Zanussi-Zdc46130s.html?page=15#manual
4/10/2023 7:26:32 PM • Zanussi Dryers • Answered on Apr 10, 2023
0helpful
1answer

Zanussi Lindo 1000 Condenser Dryer. Why has my machine started getting louder than normal.

Dry bearing and a slipping belt is the most likely reasons. A belt slipping causes vibration and squealing.
2/17/2023 5:46:52 AM • Zanussi Dryers • Answered on Feb 17, 2023
0helpful
1answer

Zanussi washing machine zwf16070w1 error code 66

Error code 66 on a Zanussi washing machine is a fault code indicating a problem with the control board. The issue could be related to the wiring, the control board itself, or a component connected to the board, such as the heater element. Since you have tested the heater element and found that it appears to be working correctly, it's likely that the issue is with the control board. However, it's always a good idea to double-check all the wiring and connections before replacing any parts. If the problem persists after checking the wiring and connections, it may be necessary to replace the control board. Replacing the control board can be an expensive repair, so it's important to consider the cost of the repair compared to the value of the machine. If the machine is old and the cost of the repair would be more than the value of the machine, it may be more cost-effective to purchase a new machine.
2/3/2023 2:02:50 AM • Zanussi Dryers • Answered on Feb 03, 2023
0helpful
2answers

Can anyone tell me the kWh of a zanussi tc7012w tumble dryer?

RTM it tells that or google it, sure does. all dryers on earth have spec and a manual and both tell that. by country too.
7/31/2022 3:41:42 PM • Zanussi Dryers • Answered on Jul 31, 2022
0helpful
1answer

Zanussi TC180W (product 916095010/01)

can be either or something else need to test using a multi meter
2/14/2022 12:32:03 PM • Zanussi Dryers • Answered on Feb 14, 2022
0helpful
1answer

Galanz error code

I have a galanz airconditioner and is showing an error be there is someone knows what does it means? Thanks
1/4/2022 7:53:24 PM • Zanussi Dryers • Answered on Jan 04, 2022
0helpful
1answer
0helpful
1answer

How do you replace the drum belt on a zanussi lindo 100 dryer

try out this youtube and see if it works for you? https://www.youtube.com/watch?v=7RzXRKa5ruQ
9/6/2019 3:36:51 PM • Zanussi Dryers • Answered on Sep 06, 2019
0helpful
1answer

Tumble dryer tc 180, working

Hi angela trent
ALWAYS UNPLUG YOUR DRYER BEFORE ATTEMPTING TO DO ANY WORK ON IT.
Check to make sure you are getting full 220 Volt power to the dryer, if you are then:
Check your Wiring
Often the main wiring connection from the house, at the dryer, burns and the connection breaks. If this has happened to your dryer, you need to replace the power cord and the terminal block inside the dryer to which the wire is attached.
Check the Door Switch
If the door switch or the door-switch actuator is defective, the dryer won't work and you need to replace the failed component. The switch is inside the dryer main housing near the door frame. Sometimes you need to raise or open the top or front of the dryer to reach the switch. Check for continuity you should have none with door open, and should have a reading when closed. If not replace the door switch.
Check to make sure you heating problem is not a lint build up in the discharge hose or the dryer,as this condition can cause heater/thermistor problems such as overheating of the heating coil leading to failure of the coil and burnout of the thermostat/thermistor due to overheat.
Remove the back/or front just under the door of the machine and try to locate the air duct going from the blower to the drum. Normally inside/outside the air duct you will find the heating coil and the thermostats/thermistors. Once you have located the heating coil, remove the two wires from it and check the coil with an ohm meter across the two terminals of the coil.
You should read continuity across the terminals, if not you will need to replace the coil as it is faulty.
If the heating coil is ok, then:
You can check the thermostat/thermistor one at a time by removing the two wires and taping them together with electrical tape.
If you have an ohm meter then you can test the thermostat/thermistor/thermal fuse,
then you do not have to tape the wires together as described above.
If the coil heats up then replace the thermostat/thermistor/thermal fuse as it is faulty.
DO NOT LEAVE THE WIRES TAPED TOGETHER AFTER THE TEST AS THIS COULD CAUSE A FIRE BECAUSE YOU HAVE REMOVED THE SAFETY.

If the thermal fuse overheats the dryer will not operate. It's located on the blower housing. It cannot be reset. A vent clogged with lint can cause it to overheat. You can test it with an Ohm meter or continuity checker, if no continuity, replace it)
Right after replacing a dryer element, always run the dryer on 'air fluff' / 'no heat', and go outside to verify there's plenty of air coming out your vent system.
If the vent's clogged, that new element can burn out very quickly.
For video and pictures on how to replace the element go to the following website:
davesrepair.com/DIYhelp/DIYreplacingWPLdryels.htm
This is a FREE answer, Please take time to rate me
1/26/2019 9:26:20 PM • Zanussi TC180W... • Answered on Jan 26, 2019
0helpful
1answer

How do i adjust belt on zanussi td 4113 w just fitted a new one and need to tighten

Check the idler pulley. Maybe it was installed incorrectly. Not aware of any adjustment capabilities of a dryer belt.
10/30/2018 6:08:05 PM • Zanussi Dryers • Answered on Oct 30, 2018
0helpful
1answer

I have a zanussi condenser dryer it wont turn on the fuse in the plug is fine please help

check door micro switch cheers
10/20/2018 5:29:07 PM • Zanussi Dryers • Answered on Oct 20, 2018
0helpful
4answers

Making an electrical noise, but drum not turning. Sounds like it's shorting.

I'd suggest - remove the top cover. Switch on. Push the drum around - see if the drum picks up speed and continues to run. If this happens, it means that the motor Starter capacitor has gone dud and will need replacing. Note- If the drum doesn't continue to rotate after you shove it, switch off immediately. It will likely then be a faulty motor.
8/16/2018 11:14:51 PM • Zanussi TC7102W... • Answered on Aug 16, 2018
0helpful
2answers

Zanussi zdc46130w Fault.

I think you should read the instruction manual . 3 beeps means some information to begin a solutin.
8/7/2018 10:22:21 AM • Zanussi TC7114W... • Answered on Aug 07, 2018
0helpful
1answer

I have a Zanussi TDS 483 EW tumble dryer it works fine but after 2-3 minutes it stops and will not re start unless put on cool tumble

your on the right ytack and they are normally easy to replace
7/21/2018 1:08:44 AM • Zanussi Dryers • Answered on Jul 21, 2018
Not finding what you are looking for?
Zanussi Logo

643 questions posted

Ask a Question

Usually answered in minutes!

Top Zanussi Dryers Experts

Brad Brown

Level 3 Expert

19187 Answers

john h

Level 3 Expert

29494 Answers

ADMIN Andrew
ADMIN Andrew

Level 3 Expert

66931 Answers

Are you a Zanussi Dryer Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides