Viking Microwave Ovens - Recent Questions, Troubleshooting & Support

0helpful
1answer
0helpful
2answers

FUSE BLOWS ON VIKING VMOS MICROWAVE WHEN YOU SHUT THE DOOR

Could be shorted wiring in the door interlock
12/7/2020 4:19:41 PM • Viking Microwave... • Answered on Dec 07, 2020
0helpful
1answer

I have a Viking Microwave that went complete dead a split second after I turned it on

1. Open internal fuse 2. Magnetron failure 3. Control board failure 4. Door interlock failure
12/7/2020 3:26:10 PM • Viking Microwave... • Answered on Dec 07, 2020
0helpful
1answer

Viking vmor205ss Micro / convection oven combo Works but does not heat anything in microwave - Got a Magnatron - still no heat Got a new high capacitor & Diode - still no heat Got all new switches and fuse - still no heat - transformer ??

Might be the transformer or the control circuit that pulses the supply to the transformer at various rates depending on the power setting selected. I would suggest you first check the transformer is receiving a good supply before you spend more money. Beware of the transformer secondary that, if it is working, produces a dangerously high voltage (typically 2 - 3000 volts) that is far beyond the capability of most multimeters.
7/21/2020 6:12:18 AM • Viking Microwave... • Answered on Jul 21, 2020
0helpful
1answer

Viking D3 micro model RDMOR200SST door button stuck in open position. What now?

Contact a microwave specialist to assess the problem!
5/31/2020 6:52:36 PM • Viking Microwave... • Answered on May 31, 2020
0helpful
1answer

Why my Viking microwave doesn't make the sound when cooking is done?

https://www.youtube.com/watch?v=_CtGVScF0sU
3/6/2020 5:07:32 PM • Viking Microwave... • Answered on Mar 06, 2020
0helpful
3answers

Scratches on microwave door

We have an over the range GE microwave and my wife was cooking some pasta on the stove and used the vent fan on the microwave to dissipate the steam and when we were done eating she noticed that the steam from the pasta had gotten in between the glass on the microwave door, how can we get rid of this any ideas.
8/17/2019 7:46:56 PM • Viking DMOR205SS... • Answered on Aug 17, 2019
0helpful
1answer

My viking microwave is stuck on half temp. I can't set it to hi. model #vmoc205ss

I would need more information to help you. Please e-mail me through my Web site with your full model number and detailed symptoms. Ed Miller http://www.microwavecontrol.com
12/15/2018 10:51:29 PM • Viking Microwave... • Answered on Dec 15, 2018
0helpful
1answer

Viking VMO200 does not microwavecook. The unit light, cooking countdown timer, clock, and panel all work. What do you think? thank you

it could be a diode a cap a switch a fuse or your magnetron you can test it by your self with avo meter good luck
6/20/2018 7:39:19 PM • Viking Microwave... • Answered on Jun 20, 2018
0helpful
1answer

MY 27 INCH VIKING PROFESSIONAL BUILT IN MICROWAVE OVEN ALLOWS ME TO SET THE TIME, BUT JUST COUNTS DOWN SILENTLY INSTEAD OF MICROWAVING WHEN PUSH START. CAN THIS BE REPAIRED? OR IS THERE A RESET?

Your bottom door switch is probably defective, or its mount is loose, misaligned, or broken. This is usually caused by opening the door while it's cooking (instead of hitting "stop" first) or slamming the door. See my help files on safety here, disassembly here, and door switches here. More questions? Contact me directly here.* * always include the full model number and FCC ID number from the label on / in your microwave (or a clear photo of the tag)
1/28/2018 10:24:08 PM • Viking Microwave... • Answered on Jan 28, 2018
Not finding what you are looking for?
Viking Logo

202 questions posted

Ask a Question

Usually answered in minutes!

Top Viking Microwave Ovens Experts

Colin Stickland
Colin Stickland

Level 3 Expert

22516 Answers

Morne Olivier
Morne Olivier

Level 2 Expert

265 Answers

Ngoro

Level 3 Expert

3513 Answers

Are you a Viking Microwave Oven Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...