U-Line Refrigerators - Recent Questions, Troubleshooting & Support
U-line bar refrig/icemaker
The fact that the compressor is two years old does not mean it cannot break down again, give more details on the problem to troubleshoot further
4/15/2021 9:52:49 AM •
U-Line...
•
Answered
on Apr 15, 2021
My uline echelon 2175RF shows
Hello, I followed your instructions, hold the up arrow and at the same time press and release the light bulb 3 times and then up arrow to 3, got the Er codes E3 and E5, now I'm trying to do the last step to go back to refrigeration cycle and it doesn't work. Help?
U-Line Model WCM48
Sorry for the delay in responding...
Most models have the valve located at the back of the machine on the lower left hand side(viewed from the front). You may have to remove the entire back cover via the hex head screws to get at it. (some models have the valve located behind the front toe kick panel.)
First follow the waterline to determine the location of the valve within the fridge. If it is at the front then the toekick panel will have to be removed. If there are no visible screws then it is most likely a clip on style. If there is a knob for temperature setting then the knob may have to be pulled off first.
If there is a smaller cardboard panel at the bottom rear of the fridge remove it and you should see the valve. If not then remove the entire back cover by removing the screws along the rear perimeter of the fridge. The panel may stick to the back of the fridge but gently pull and it will remove. The valve should now be seen and can be disconnected.
Be sure to unplug the machine first and turn off the water supply. There will still be some pressure in the waterline so have a towel ready.
The valve itself is available online, I think the correct one is located at: http://www.repairclinic.com/SmartSearch/SSPartDetail.aspx?PartID=832567&PPStack=1
Just be sure to verify that it is the right one before ordering.
12/18/2020 4:14:55 PM •
U-Line...
•
Answered
on Dec 18, 2020
The alert notification is from a u-line refrigerator and beeps even when door fully closed
Since you did not mention what make it is .
Its usually dirt in your door seal causing your refridgirator to understand its not closed since its not sealing properly . clean the door seals and try .
Or there is a technical glitch in electrical system and you need a repairman .
Also there is usually a way to disable the alarm and you need to check your user manual for that to disable it ill its fixed
6/1/2018 4:50:59 AM •
U-Line...
•
Answered
on Jun 01, 2018
I have an U-Line model
the condensate drain pump will shut unit down and only run drain pump if over fill is seen may be noise you are hearing
if condensate pump removed has to be wired so kill switch in drain pump is over ridden for gravity drain
11/15/2017 4:29:51 PM •
U-Line...
•
Answered
on Nov 15, 2017