Predator generator 4000 problems idle speed up and down

Engine surge/governor hunting are usually a carburetor issue. First check air filter, drain fuel tank, drain and clean carburetor fuel bowl. Then use fresh fuel from a clean dry fuel can. If its still hunting, check that the carburetor mounting bolts are not loose. If carburetor mount is good, then the carburetor likely needs cleaning or replaced. You could also try SeaFoam or other similar fuel treatment. Just follow label directions, usually 1 oz / gal... measure don't guess.
1/18/2019 1:42:35 PM • Speed Electrical... • Answered on Jan 18, 2019
0helpful
3answers

A diesel engin uses diesel fuel generates low power at low speed

Increase the speed for constand power output, or check the load it maybe more than the genset can power.
9/11/2018 6:59:51 AM • Speed Electrical... • Answered on Sep 11, 2018
0helpful
2answers

Generator starts before it gets upto speed the frequency and voltage lights flash and the generator shuts down within 30 seconds from start. What is the problem?

Mybe power from the commercial supply had failed . Or power surge occured and the genset detected power failure. The other cause could be air bubbles in the gasoline.The genset may need bleeding to remove air bubbles in the gasoline.
9/1/2018 6:57:29 AM • Speed Electrical... • Answered on Sep 01, 2018
0helpful
1answer

Where can I buy replacement knobs for dual slider dimmer and fan speed switch? Mine cracked and fell off

Sorry but we do not have a parts locator service at this website.
10/6/2017 7:34:27 PM • Speed Electrical... • Answered on Oct 06, 2017
0helpful
1answer

My generator isnt kicking down when its supposed too, it runs at continuous speed

An AC generating set runs at a continuous speed in order to produce current at the correct Hz - 60Hz in the USA and 50Hz almost everywhere else. The built-in governor will maintain the preset speed, opening and closing the throttle automatically as a load is plugged in or removed.
4/6/2017 1:02:26 AM • Speed Electrical... • Answered on Apr 06, 2017
0helpful
1answer
0helpful
1answer
0helpful
2answers

Changing the 3 speed switch on my westinghouse ceiling fan

If you are careful and take the hot coming into the fan from the power source and connect it to the colored wires one at a time, you will be able to find which one is high, med. and low. Then connect them. Hot in is L, 1 is low, 2 is med, 3 is high If you need further help, I’m available over the phone at https://www.6ya.com/expert/craig_3fa289bf857b1a3c
5/10/2014 5:54:02 PM • Speed Ceiling... • Answered on May 10, 2014
0answers
Not finding what you are looking for?
Speed Logo

46 questions posted

Ask a Question

Usually answered in minutes!

Top Speed Electrical Supplies Experts

Sean Wright
Sean Wright

Level 3 Expert

2045 Answers

Brad Brown

Level 3 Expert

19187 Answers

john h

Level 3 Expert

29494 Answers

Are you a Speed Electrical Supply Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...