Sharper Image Air Purifiers - Page 3 - Popular Questions, Answers, Tips & Manuals

0helpful
1answer

My Ionic Breeze machines are pretty old and do not stay clean for very long before they start crackling. They are also exhuding a noticable ozone odor. Are they still safe to use and cleaning our air?

They need a very thorough cleaning. You can use a soapy solution 1st, then wipe them dry. Then follow with a 50/50 solution of water & vinegar. Clean well on all the metal cells, then rinse wipe with damp cloth then wipe as dry as you can. Allow to dry overnight, ensure that the cell is very dry prior to starting. Then final thing - keep inverting upside down then right side up numerous times. You want the little beads to slide up & down the wire. This will clean that as well.
1/29/2014 3:47:53 AM • Sharper Image... • 150 views • 0 helpful votes
0helpful
1answer

I need to replace steel wire in quadra s1837/were to buy

I saw where one person replaced them with piano wire. Must be sure that the diameter is correct so the cleaning beads will slide up and down on the wire.
11/20/2013 8:29:06 PM • Sharper Image... • 346 views • 0 helpful votes
0helpful
1answer

I have a Sharper Image Ionic Breeze GP S1730 the

One person used piano wire, but the diameter must be right so the cleaning beads can slide up and down on the wire when the unit is turned up and down.
10/22/2013 1:30:38 AM • Sharper Image... • 685 views • 0 helpful votes
0helpful
1answer

1 thinks its wet , 1 sparks and snaps.

I took the blades and a washrag in the shower with me and cleaned them. Then I put them in front of the air vent for 8-10 hours. Then I put them back in the unit. Sparking and snapping could be from dirt moving through the unit.
11/21/2013 2:37:10 PM • Sharper Image... • 253 views • 0 helpful votes
0helpful
1answer

I was cleaning the grid on a Iconic Breeze GP professional series and i forgot to unplug before pulling it out now the unit wont work...is it a fuse? ...or what would be the nature of the repair now?

I never unplugged any when cleaning, I just turned it off with the switch. Could be that the collector blades are not dry when you put them back in the unit.
11/20/2013 6:32:24 PM • Sharper Image... • 138 views • 0 helpful votes
0helpful
1answer

Ionic breeze air purifier will not work

Bad limit switch for the removable fin bar Connected the red wires together
3/15/2013 6:05:45 PM • Sharper Image... • 490 views • 0 helpful votes
0helpful
1answer

Does the ionic breeze blow air

They only move the air slightly. They are not like a conventional fan.They do not rotate. They do work effectively for mold spores and dust. If yours has not been cleaned in a while remove the front element from above and spray the stainless bars down with an acidic claener like "Formula 409" and wipe them down after rinsing. On the unit itself unplug it and remove the front and rear grill br pressing a small tab at the bottom of the grille and push upwars. Be careful with front grille as there is an ionizing wire there towards the inside of the unit. If the unit has come from someone else, with an emery board and gentle pressure just make one pass witht he wire gently between board and your finger. drawing towards the spring loaded end. Do the same to the two wires inside the unit housing if present, Witht he rear grille removed, remove the bulb and wipe it down with a cleaner if needed- it should be clear. as it is a UV bulb.Dust out hte base area with a small paintbrush and remove as much dust as you can from it. If need be a slighly damp rag cna also be used. With the front of the Ionic breeze unit facing you, there are 2 conductive rubber strips that also need to be wiped down with a lsightly damp rag. They should be removing some black dust. Also wipe down the inside of the front being mindful of the two stainless wires. Let unit dry off and reassemble.With left knob turned to left- no light should appear. Turn knob to the right and the UV tube should light and the Boost button should light up blue when pressed once- and green when pressed a second time and then off if pressed a third time. It will only light when the left knob is turned to right. The right knob adjusts "Low," "Medium" and "High" intensity of the high voltage applied to elements.Alow unit to dry before powering it on.A working system should raise the hairs on the back of you hand or give you some other sensation of moving air
9/29/2012 3:12:39 AM • Sharper Image... • 927 views • 0 helpful votes
1helpful
2answers

TRYING TO FIND REPLACEMENT PARTS FOR A SHARPER IMAGE HYBRID GP GERMICIDAL AIR PURIFIER MODEL SI724 NEED THE WIRES AND BEADS TO REPLACE SOME BROKEN ONES

I have 2 of these air purifiers and I love them. I came to this site looking for a resolution because 1 of them stopped working properly. After running for about 30 seconds, the red light would come on. I had cut out 1 wire that was broken and thought that was the problem. There were sparks when it was turned on. After reading a couple answers here, I took a closer look and noticed that a second wire was also broken at the bottom. I just cut the second broken wire off the top and removed it and the purifier works great now. No more sparks!
8/16/2012 4:16:28 PM • Sharper Image... • 1,151 views • 1 helpful votes
Not finding what you are looking for?
Sharper Image Logo

725 questions posted

Ask a Question

Usually answered in minutes!

Top Sharper Image Air Purifiers Experts

Cindy Wells

Level 3 Expert

6688 Answers

Sean Wright
Sean Wright

Level 3 Expert

2045 Answers

Jay Finke
Jay Finke

Level 3 Expert

1397 Answers

Are you a Sharper Image Air Purifier Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides