Sharp Refrigerators - Page 3 - Answered Questions & Fixed Issues

0helpful
1answer

I hear a sharp snap then a loud humming noise which sounds electrical. If I turn the refrigerator switch off, then on, the humming stops. Otherwise, it lasts 10 to 15 minutes. Its getting louder.

DID U CHECK UR EVAPORATOR FAN AND LISTEN IF THE NOISE IS COMING FROM IT? COULD BE BROKEN OR IMPEEDED IMPELLER HITTING SOMETHING ON START UP THEN GOING INTO A HUM? hear-sharp-snap-loud-humming-noise-kvax0h5nolktkyinzrohy2he-2-0.jpg hear-sharp-snap-loud-humming-noise-kvax0h5nolktkyinzrohy2he-2-2.jpg hear-sharp-snap-loud-humming-noise-kvax0h5nolktkyinzrohy2he-2-5.jpg hear-sharp-snap-loud-humming-noise-kvax0h5nolktkyinzrohy2he-2-9.jpg hear-sharp-snap-loud-humming-noise-kvax0h5nolktkyinzrohy2he-2-15.jpg
5/20/2015 6:15:59 PM • Sharp... • Answered on May 20, 2015 • 223 views
0helpful
1answer

How do I fix the short circuit that's preventing the refrigerator from cooling?

FREEZER /FRIDGE NOT COOLING: Optimum refrigerator temperature at or below40° F(4° C). The freezer temperature should be0° F(-18° C). Check temperatures periodically. Appliance thermometers are the best way of knowing these Check ur cold control thermostat, ur thermistors in both fridge and freezer ( they should be checked for both ohms and for amount of current being put out as per ur model ), ur air flow vent from freezer to fridge.( to make sure it opens and closes without any restrictions) On thermistors check for A close circuit and amount of ohms not just an Ohm reading. As per ur model. Most should atleast show 1200 ohms. Also Check door seals for leakage. Evaporator coils Poor cooling is often the result of a heavy frost build-up on the evaporator coils. You can't see these coils without removing a panel on the inside of your freezer. A sure sign that there is a build-up is the presence of any frost or ice build-up on the inside walls, floor, or ceiling of the freezer. Such a frost build-up usually indicates a problem in the self-defrosting system or damaged door gaskets. If one of the components in the self-defrosting system fails, the refrigerator continues to try to cool. Eventually, though, so much frost builds up on the evaporator coils that the circulating fan can't draw air over the coils. There may still be a small amount of cooling because the coils are icy, but with no air flow over the coils, cooling in the refrigerator compartment is quite limited. FAN check to see if it is operating or restricted A fan that is not blowing or restricted will not circulate the cold air properly. Often, the first thing that folks do when their refrigerator starts to feel warm is turn both controls on the coldest settings.This is exactly the WRONG thing to do.Turning the cold control to the coldest settingwillkeep the compressor running longer and make lots of cold air. But turning the air door to the coldest settingclosesthe airway to the food section. Lots of cold air is made, but most of it stays in the freezer section, and the food section actually getswarmer. Condenser Self-defrosting refrigerators all have a set of coils and a cooling fan, usually under the refrigerator, that need to be cleaned regularly. If these coils get coated with dust, dirt or lint, the refrigerator may not cool properly. The coils may appear to be a thin, black, wide radiator-like device behind the lower kick-panel. To clean them, disconnect the refrigerator from the power source, use a refrigerator condenser brush and your vacuum cleaner to clean the coils of any lint, pet hair, etc. You may not be able to get to all of the condenser from the front, it may be necessary to clean the remainder of the condenser from the rear of the refrigerator. May also need to check the defrost timer, u can get by and test manually by placing a small screw driver into the tiny slot or hole underneath the timer and turn slowly clockwise till u hear 1 click. this will engage ur defrost cycle in about 15 minutes u should be able to come back and feel the heat in freezer as it melts the ice providing ur terminator is not bad? Another way to test it is with a multi meter. Remove timer it from fridge and you will see 4 prongs numbered 2,1,4,3 in that order. Place ur meter prong on prong 1 & 3 (if your fridge has a capacitor wired in series with the windings, then u check for micro fares rather than OHMS) If u cannot confirm this test, still try the next. Take ur meter prong and connect to prong 1 & 4, it should read resistance or ohms ( closed) now remove prongs and place on prong 1 & 2, this should now read infinity or open (no ohms) now take a small screwdriver place it in the tiny hole or slot under the timer. Turn it clockwise slowly till u hear 1 click. Now ur 1& 2 should read closed ( showing ohms or resistance) now place meter prongs on 1 & 4 and you it should now show open ( or no resistance - no ohms) this is how u know ur timer is good, Remember when testing for ohms ADJUST meter to use a high ohms rating in the thousands as the resistance is very high in OHMS. And adjusting to low ohms rating may give a false reading or not show the proper resistance.. THE COMPRESSOR: If you hear a clicking sound coming from the back of your refrigerator/freezer, then the problem is most likely the compressor, relay and or capacitor is overheating or not getting proper power and will not start.The compressor is the component on your refrigerator that allows your refrigerator to cool. If this component is not working properly your refrigerator will stop cooling. Most of the time the compressor is not the component that has failed. To check ur compressor with multi meter: Disconnect and remove the relay and capacitor from compressor, some located next to compressor in a casing. You wills see 3 prongs coming out of compressor. 1 goes to ur srtart winding, 1 goes to ur run winding and the center goes to ur ground. Place ur meter connector or prong on the start prong and the other on the ground (center prong) take note of the reading in OHMS for example 5 ohms. Next place meter prong on run prong and the center ground prong agin. Take note of the reading in OHMS. Example 4 ohms Next place meter prong on the start prong and the other on the run prong, now take note of the reading example 9 ohms. Now match the total of this ohms test with the total of ur two separate test. 9 ohms, if they match ur ok give or take 5 percent plus or minus. One more test to make to test of there is a short in compressor attach meter prong to ground prong and rub the other end of meter prong to metal ( scrape the metal clean of paint and test on metal surface not painted surface. If it shows continuity or ohms , u have a short in ur compressor. It should show infinity Lastly you should also check ur THERMISTORS in the freezer and fridge section for continuity OHMS and for amount of OHMS current being put out. In most models around 13000 ( give or take 150 ohms) ohms is required. Read more:http://removeandreplace.com/2013/10/31/fix-refrigerator-freezer-wont-cool-freeze/#ixzz3WDEo5NDJ REMEMBER GOD IS THE REASON FOR GOOD ADVICE"
5/12/2015 7:14:58 PM • Sharp... • Answered on May 12, 2015 • 149 views
0helpful
1answer

Water under the veg. compartment in sharp SJ-T520R-SL refridgerater

Hi,at the back of the fridge there is useuly a drain hole if its blocked then instead of the water going out of the back of the fridge its staying in the fridge,if there is one just get a peice of wire and push down hole to remove any blockidge,also what can couse itis if your food in the fridge is tuching the back off the fridge wall then the water runs down the food inside the fridge instead off going down the drain hole. hope this was some help,all the best.
4/19/2015 9:58:56 AM • Sharp... • Answered on Apr 19, 2015 • 348 views
0helpful
1answer

Sharp Fridge is collecting water under veg compartment

Drain Try is full with water its fix on compresser. Empty Drain try and try.
3/3/2015 12:34:17 PM • Sharp... • Answered on Mar 03, 2015 • 7,270 views
0helpful
1answer

I got sharp SJ41M can i reverse the doors to open from left ?

No this is not possible.
3/3/2015 12:32:45 PM • Sharp... • Answered on Mar 03, 2015 • 116 views
0helpful
1answer

Freezer not cooling

Freezer Fan is not working or Gas leaked from Compressor line.
3/3/2015 12:32:02 PM • Sharp SJPT640RS... • Answered on Mar 03, 2015 • 105 views
0helpful
1answer

Is sharp non-cfc refrigerator power saving?

Checked any gas leaked from compressor.
3/3/2015 12:31:10 PM • Sharp... • Answered on Mar 03, 2015 • 186 views
0helpful
1answer

My refrigerator's evaporator partially frozen. why?

Most of this problem with Freezer fuse.
3/3/2015 12:30:18 PM • Sharp... • Answered on Mar 03, 2015 • 63 views
0helpful
1answer

My sharp SJ-F70PV-SL is not cooling properly

Switch off your ref for 8hrs till all Ice melt in freezer compartment. Switch on Ref and checked Air coming from Ref duct or not.
3/3/2015 12:25:08 PM • Sharp... • Answered on Mar 03, 2015 • 932 views
0helpful
1answer

How to open the sharp sj-3555-wh refrigerator's freezer compartment for cleaning

Switch off your ref for more then 8 hrs and checked all ice melt after that you can adjust all attachment .
3/3/2015 12:22:26 PM • Sharp... • Answered on Mar 03, 2015 • 299 views
0helpful
1answer

My sharp freezer model SJ-229S-SL , UPPER IS WELL BUT BOTTOM NO COLD

Checked Damper in Ref its working or not. You can checked open Ref door press Door Switch and hold your hand near chiller tray Duct
3/3/2015 12:15:30 PM • Sharp... • Answered on Mar 03, 2015 • 222 views
0helpful
1answer

Sharp sj-19tgl refrigerator not cooling

Checked Thermostat and replaced.
3/3/2015 12:13:23 PM • Sharp... • Answered on Mar 03, 2015 • 657 views
0helpful
1answer

Stop alarm beeping

Main PCB Defective
3/3/2015 12:12:26 PM • Sharp... • Answered on Mar 03, 2015 • 42 views
0helpful
1answer

Light not working

Model No required if two door you can open Glass of Lamp after that open two nut and replaced with same one.
3/3/2015 12:12:00 PM • Sharp... • Answered on Mar 03, 2015 • 46 views
0helpful
1answer

Not cold enough

Adjust Freezer Temp center and ref also in center
3/3/2015 12:10:19 PM • Sharp... • Answered on Mar 03, 2015 • 50 views
0helpful
1answer

Water leaking from hybrid cooling panel

Checked Drain pipe behind ref on top Compressor is not full of water
3/3/2015 12:09:22 PM • Sharp... • Answered on Mar 03, 2015 • 57 views
0helpful
1answer

My sharp freez not cool

You can checked error with pressing select button for 5 second while Ref door open. If any defect in your ref error will display.
3/3/2015 12:08:27 PM • Sharp SJPT640RS... • Answered on Mar 03, 2015 • 86 views
0helpful
1answer

My freezer is freezing up and we can't move the control at the back of the freezer

Switch off your Fridge for 24 hrs and after that start. Before starting adjust control to minimum.
3/3/2015 12:06:19 PM • Sharp... • Answered on Mar 03, 2015 • 45 views
0helpful
1answer

How do I adjust the doors on a sharp sj-f60pc

You can open 3 Screw on top and adjust door.
3/3/2015 12:00:46 PM • Sharp... • Answered on Mar 03, 2015 • 196 views
Not finding what you are looking for?
Sharp Logo

Ask a Question

Usually answered in minutes!

Top Sharp Refrigerators Experts

Cindy Wells

Level 3 Expert

6688 Answers

Brad Brown

Level 3 Expert

19187 Answers

ADMIN Andrew
ADMIN Andrew

Level 3 Expert

66851 Answers

Are you a Sharp Refrigerator Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...