Hi! I have Ridgid OL50145MW Air Compressor.
It seems like the compressor head is not pumping air.
No air pressure at all on gages at all? No air leaks? disconnect the compressor head (t- joint) and varify air is or is not being pumped.
Compressor air inlet filter section, you can also varify that air is being sucked in to the compressor head there by the pump action.
7/7/2018 9:33:52 PM •
Ridgid...
•
Answered
on Jul 07, 2018
Compressor wont shut off
Check your wiring, Line to line, load to load. Line is power coming in, load is to the motor. Check for packing that should have been removed. Inspect the pressure switch contacts to make sure they open at desired psi and adjust as necessary. A nut or screw pushing on a spring adjusts tank psi. Loose unloaded spring is less pressure, tight compressed spring is more pressure before cut off..