Philips Health &... | Answered on Dec 07, 2020
Philips G380... | Answered on Mar 28, 2020
Philips Norelco... | Answered on Mar 01, 2020
Philips Health &... | Answered on Dec 01, 2019
Philips Health &... | Answered on Oct 29, 2019
Philips Health &... | Answered on Jun 19, 2019
Philips FR2+ Aed... | Answered on Mar 07, 2019
I have had three 1050CC shavers all with the same problem. Apparently other models have the same issue. After about a year of use, the unit reverses after dipping the shaver into the cleaning solution for a second. Two were replaced by Philips within the 2 year warranty period. I still use the 3rd one. There are several things you can try. If the cleaning solution is low this will cause the shaver to reverse and not clean. Add more cleaning solution. I have noticed that sometimes I have to add more fluid to the unit after a week of use. Sometimes it is necessary to fill the solution a little above the max fill line. Be careful though. Filling it too much above the max fill line can cause cleaning fluid to run out of the bottom after a cleaning cycle. If the above two fixes don't work, then press the clean button and after the unit reverses back up, wait about 5 or 10 minutes and press it again and it should stay down as long as there is enough cleaning solution in the unit. If you wait too long or too little to press the button, it won't work. I have noticed if I press the button immediately after it reverses the same problem occurs. Also if I wait 30 minutes before pressing the button the same problem occurs. There must be some sort of timing cycle. You may have to repeat this process a few times to get it to stay down and clean. This is the only way I can get mine to clean now. Obviously something is getting dirty or wearing out over time in the cleaning system. Since I have had 3 shavers with the same problem, I know many others have had it too. Philips must be aware of the problem. It is frustrating that they don't offer help on their own website and consumers have to band together to solve problems that they should be solving. The two year guarantee is very generous, but there is a design flaw with this product.
Philips Norelco... | Answered on Feb 24, 2019
Philips... | Answered on Feb 15, 2019
Philips... | Answered on Jan 17, 2019
Philips Health &... | Answered on Nov 24, 2018
Philips Health &... | Answered on Oct 26, 2018
Philips Health &... | Answered on Sep 30, 2018
Philips Norelco... | Answered on Jul 24, 2018
Philips Health &... | Answered on May 11, 2018
Philips Health &... | Answered on Apr 02, 2018
Philips G370... | Answered on Feb 17, 2018
Philips Health &... | Answered on Feb 08, 2018
1,093 questions posted
Usually answered in minutes!
42 Questions
47 Questions
35 Questions
32 Questions
29 Questions