The unit switches off after exactly 10 minutes

You have to try resetting the system. First turn the breaker off for the condenser and wait about 20 seconds. After you turn it back on the system should reset. Air Conditioning West Palm Beach
5/13/2015 6:48:39 PM • Mitsubishi... • Answered on May 13, 2015 • 117 views
0helpful
1answer

The conditioner stays on for 3 mins on cool and heat and then turns off and the left light continously flashes.

Typically means that your refrigerant level is very low.
5/7/2015 3:30:27 PM • Mitsubishi... • Answered on May 07, 2015 • 83 views
0helpful
1answer

Thermistor for Mr. slim Mitsubishi circuit board

Not sure which unit you have, here a website that might help. Mitsubishi Electric Sales Canada Inc Air Conditioning Heating
4/9/2015 2:32:25 PM • Mitsubishi... • Answered on Apr 09, 2015 • 1,418 views
0helpful
1answer

Why does mitsubishi split system heats room 5 degrees hotter than setpoint on remote

It could be something as simple as 'solar gain' adding heat through glass facing the afternoon sun....or maybe the remote is not in a location that senses the average temperture within the room. Maybe the remote is located in a slight draft entering the room. If the remote was kept above a computer tower, the opposite would be the case.... the heat from the tower would keep the control thinking its warmer in the room than it is. The result would be a much colder room.
3/13/2015 5:28:54 PM • Mitsubishi... • Answered on Mar 13, 2015 • 162 views
0helpful
1answer

I need a spare filter for my Mitsubishi R410A Aircon what is the filter number and where to buy?

Supposedly if you have the old filter you can wash it with baking soda. I can't locate the parts. You might have to contact a factory authorized dealer to purchase the filter if it requires replacement.
2/21/2015 3:13:10 AM • Mitsubishi... • Answered on Feb 21, 2015 • 105 views
0helpful
1answer

How do I get MR Slim out of standby mode

if unit is hard wired try turning circuit breaker off and then back on
2/15/2015 6:21:51 AM • Mitsubishi... • Answered on Feb 15, 2015 • 5,311 views
0helpful
1answer

My Mitsubishi split aircon stops after a couple of minutes, and green operation light flashes. I have checked filters and timer, both OK. Will turning it off at the main switch board reset things?

your main board more so the pipe sensor connected to it, is defective. if the pipe senor can be changed it will work but in most cases the whole main-board will have to be changed as well.
2/8/2015 3:07:51 AM • Mitsubishi... • Answered on Feb 08, 2015 • 557 views
0helpful
1answer

Troubleshooting error code Mitsubishi Heavy VRV System split

MITSUBHISI CITY UNIT VRV fault code 5301
1/15/2015 7:03:16 PM • Mitsubishi... • Answered on Jan 15, 2015 • 372 views
0helpful
1answer

Turn a mitsubishi H1 split system modelsrk80z ea-s2 from hot to cold mode

there you go a link to the user manual, chers! Users Manual For Mitsubishi SRK63ZEA S1 SRK71ZEA S1 SRK80ZEA S2 Air...
1/7/2015 2:21:12 PM • Mitsubishi... • Answered on Jan 07, 2015 • 309 views
0helpful
1answer

Why my mitsubishi air con blinking 6 times ?

that is only half the code you need the remote an lots more steps to troubleshoot that conditioner here is some simple steps . but id get help on this. http://www.daikin.com/products/ac/services/troubleshooting/ after that comes this step an its exacting AstiquerMold Control Air con Specialist in that page at the top is the command for your unit to ask it what code its tossing.
1/5/2015 3:33:03 AM • Mitsubishi... • Answered on Jan 05, 2015 • 1,548 views
0helpful
1answer

Mitsubishi heat pump blows cool air when set on 70 in heat setting. It will be 3 years old in January.msz-fe18na

Cooler than normal discharge air temperatures are kind of nature of the beast for an inverter compressor system. An inverter compressor has essentially an infinitely variable output due the varying speed of the compressor. When is is running slower the transfer of heat is less than when it is running full bore. At least on a mild day. On a cold day, even running at full speed, the leaving air temperature can feel a bit cooler due to the lack or heat available in the outside air to transfer in to the indoor coil. The Mitsubishi's are capable of running down to 5 degrees above zero without the addition of a low ambient control kit and the nearer it is to that temperature, the lower the leaving air temp will be. There's only about three more 300 page VOLUMNs of information available to describe the function of these little guys, but maybe just a taste of the info will satisfy your concern. Of course what's written above is a very Cliff Notes version with a lot of holes in the description.....but you get the drift.
1/4/2015 6:33:49 PM • Mitsubishi... • Answered on Jan 04, 2015 • 916 views
0helpful
2answers

I am not able to get the unit to change from air conditioning to heat

Unfortunately these units are not user fixable , beyond checking for power and checking battery in remote. You would need to call a pro who is able to get service information and has special digital logic meters to diagnose and repair .
12/28/2014 11:36:20 AM • Mitsubishi... • Answered on Dec 28, 2014 • 488 views
0helpful
1answer

We have a new outside ms24wn and have access to the gas but need an inside blower unit for it.

Might try finding an appliance shop near you who maybe able to find parts or refer you to where you may find them.
12/2/2014 10:20:23 PM • Mitsubishi... • Answered on Dec 02, 2014 • 74 views
0helpful
1answer

The air conditoner will not turn on the remote works but the unit itself wont go on is there a fuse in it

The newer air conditioners have a button on the actual plug. It is a reset breaker switch. Try pushing the button on the plug while it is plugged in. (Assuming it has one)
12/18/2014 11:21:52 PM • Mitsubishi Mr.... • Answered on Dec 18, 2014 • 513 views
0helpful
1answer

Mr slim ac shuts down and restarts to frequently.

Changing the setting won't affect the way the unit works, only how long it runs for. Rapid switching off and on will kill your compressor in time - check the refrigerant level. Usually short cycling on lp switch.
1/22/2015 11:35:29 PM • Mitsubishi Mr.... • Answered on Jan 22, 2015 • 424 views
0helpful
1answer

How do i dismantle the aicon unit

First thing u have do is pumpdown the unit close discharge line wait for few seconds check the suction line when coolness of suction line goes also close the suction valve and then dissconect all power supply then u can remove copper tube and easily dismantle a/c unit.
10/5/2014 9:11:07 PM • Mitsubishi... • Answered on Oct 05, 2014 • 90 views
0helpful
1answer

What is the black stuff blowing out of vents?

Mold. Moldy dust. You need to clean your unit.
9/28/2014 8:48:48 PM • Mitsubishi Mr.... • Answered on Sep 28, 2014 • 690 views
0helpful
1answer

My split ducting unit cools when started only

Is your outside coil dirty wash it this may help. Sounds like your head pressure is getting to high and the compressor is kicking out on thermal overload.
9/19/2014 1:12:22 AM • Mitsubishi Mr.... • Answered on Sep 19, 2014 • 190 views
0helpful
1answer

My Misubishi A/C leaks periodically

clean the filter first then take a shop vac and suck out your condenstate drain line on the outside. Look at the inside coil to see if its dirty if it is clean it.
9/6/2014 11:28:22 PM • Mitsubishi Mr.... • Answered on Sep 06, 2014 • 255 views
0helpful
1answer

Mr slim remote not working?

If you put you phone on to camera mode. Hold the remote with the top facing the camera into the phone. Press on and off button on remote. If your remote is working. You should see a light come on through your mobile phone screen. If it is not. A new remote is required. I use a universal remote.
8/28/2014 8:29:34 PM • Mitsubishi Mr.... • Answered on Aug 28, 2014 • 2,433 views
Not finding what you are looking for?
Mitsubishi Logo

Ask a Question

Usually answered in minutes!

Top Mitsubishi Heating & Cooling Experts

 Mikey
Mikey

Level 3 Expert

6904 Answers

vince

Level 3 Expert

2530 Answers

Brad Brown

Level 3 Expert

19187 Answers

Are you a Mitsubishi Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...