Heater won't stay on
This product does indeed have a problem with the safety switch, that is only supposed to kick in when the unit is turned over. I had a total of 3 units sent to me from Kaz. Each time the unit would work for a short time, then slowly begin to turn off and on. I finally decided to take the unit apart and look for any obvious problems. There is a weighted swivel that will raise a contact point to turn the unit off in an emergency. The contact points would spark off and on, depositing a black carbon on them until they would no longer allow power to pass through. I cleaned the contacts with a fine finger nail file and bent one of the contact arms inward to make better tension between the contacts. This allowed the unit to stay on for longer periods of time. But even with the thermo-stat turned all the way up, the unit does not stay on long enough to heat the room. In effect, what happens is the contacts will continue to ark, putting black deposits on the contacts until you're back to square one. Apparently the unit also has a thermo-stat related problem. I'm sending the unit back again (they only made me send the power cord last time), but will insist on a different model this time. Good Luck
Reset filter
The solution is simple. Just press on the little red light that says to reset filter. Its a button that will reset the warning and the light should go out
12/28/2011 9:56:11 AM •
Kaz Honeywell...
•
Answered
on Dec 28, 2011
•
3,825 views