Fasco Water Heaters - Recent Questions, Troubleshooting & Support
We have a Bradford White Hydrojet Gas Water
here's what Bradford White lists....
Burner Will Not Ignite
REASON
REMEDY
Excess primary air
Adjust air shutter to reduce air supply -- if supplied
No gas
Check with utility
Dirt in main burner orifice
Clean orifice -- check for source of dirt and eliminate
Dirt in gas lines
Notify utility -- install dirt trap in gas line
Venturi clogged
Clean -- check for source of trouble and correct
Pilot line clogged
Clean -- check for source of trouble and correct
Main burner line clogged
Clean -- check for source of trouble and correct
Defective thermocouple lead
Replace with new thermocouple lead
Defective thermostat
Replace
Defective magnetic valve
Replace entire control
Thermostat set too low
Turn temperature knob to desired temperature
Heater installed in confined space
Provide ventilation by use of louvers in wall or door
time for a service tech.
Why is the water running out of my water heater slowly?
If you take your pipe off the hot side of the water heater, there is a check valve in the pipe that is stubbed up. They vary in style, usually it is like a marble and it gets stuck. It is easier to replace the stub with a brass nipple and put the dielectric fitting back on it.
How do I get rid of the sulfer smell in my hot water?
As soon as you pull out the anode rod(and not put it back) the walls of the tank will begin to rust. The sacrificial anode is there for a reason. If it's eaten away, replace it. If it's totally gone, the tank has been being attacked for a while and might be due for replacement.
Noisy barring motor
bradford white blower . Sir this link will provide you with a variety of sources to buy the blower. The average is far below your quoted target. Since this is a nut and bolt with a direct plug or 3 wire assembly,
bradford white blower 239 40614 00 . Here lies a different price point.
If this blower is out of warranty and its been running a long time. The value of the direct replacement is a far better choice to average, although more, odds; are to revisit it sooner than later without a direct replacement.
If you need help to do this job? It can be a do-it -yourself. Make sure the unit is locked out and give it a whirl. If not? The replacement is approximately 2/3 that of your suggested quote. The ball is always in your court.
Be safe. Carbon Dioxide does not discriminate, you never hear anyone from the cemetery complaining. If this is iffy. Get a technician. The extra 1/3 may justify the worth of a life investment. Fare. Well.
Load condenser fan
MOre information is needed in order to have your question. What are you trying to ask with the statement "Load condenser fan".
Making noise when running
PUMP check it out does the boiler sound like a kettle boiling if so its over heating and needs descaling
Our Hydrojet gas water heater stopped producing
This could be caused by a defective thermocouple,gas valve, limit switch, clogged spud or anything else. More information is needed. Gas equipment should not be serviced by novices. Save your life and property. Hire a professional!