How do I remove the front dispenser panel to replace the ice path shutter?

On the bottom edge of the panel there are two tiny slots in the plastic. Take a flat blade pocket screwdriver, insert the blade in the slot and pry it off .
1/1/2016 7:18:53 PM • Beko GNEV321APX... • Answered on Jan 01, 2016
0helpful
1answer
0helpful
1answer

I have a Beko frost free fridge freezer .The freezer is working ok but fridge is far too cold and is freezing everything

Adjust the thermostat inside the refrigerator to a lower number.
11/1/2015 8:26:22 AM • Beko... • Answered on Nov 01, 2015
0helpful
1answer

The ice tray not filling up

The ice tray has a lever sensing the load of ice; when the ice is pushing 'UP' it can get hung up. Reach the arm and pull it down.
10/31/2015 12:28:34 AM • Beko... • Answered on Oct 31, 2015
0helpful
1answer

Please help ..my fridge is swelling on inside back wall where my shelves are protruding can anyone help please its a beko xx

Sounds like you have moisture in there and it's freezing causing swelling. Sounds like you need to defrost- really defrost your fridge. Remove the food to somewhere else, FIRST unplug the thing, open the doors and use fans to blow air in there to melt any ice in the unit. Be prepared to mop up lots of water.from the floor and keep emptying your pan under the fridge if it has one. This can take a whole day to get done and maybe a day and a night.
10/15/2015 2:26:02 PM • Beko... • Answered on Oct 15, 2015
0helpful
1answer

I am thinking of purchasing a Beko Freezer Model Number TZ3490 could you tell me how old this model would be.

I cannot tell you how old it is, but I can tell you that it must be much older than 10 years. You cannot find parts for that model anymore.
9/11/2015 6:39:07 PM • Beko... • Answered on Sep 11, 2015
0helpful
1answer

M beko ffridge freezer is not defrosting it's got snow in the fridge put new board in it still not defrosting

Check the defrost timer and/or defrost heater element for proper operation.
8/12/2015 1:46:55 PM • Beko... • Answered on Aug 12, 2015
0helpful
1answer

Not getting cold Beko fridge

recharge it
7/6/2015 11:10:19 AM • Beko... • Answered on Jul 06, 2015
0helpful
1answer

Hi what setting from 1 to 4 do I need to set my new Beko freezer on

THE MEDIUM SETTING IS USUALLY THE BEST SO SET AT 2
5/22/2015 9:56:17 PM • Beko... • Answered on May 22, 2015
0helpful
1answer

I have recently purchased a beko GNE60520 DX and i can not work out to get the ice machine to make ice, i have read the user manual from top to bottom and the troubleshooting but my answers were not t

ICE MAKER not making ice Inspect Water fill tube, Inspect the ice maker mold to see if there are ice cubes present. If there are no cubes or very small cubes, then you should look for issues with the water fill system. Inspect the fill tube and the fill cup area at the back of the ice maker to make sure that they are not frozen. If there is an ice buildup in that area, confirm no foreign objects have disrupted the flow of water into the fill cup. If nothing obvious has caused the ice buildup then suspect the inlet valve, tubing or low water pressure. Inspect the outlet tubing from the fill valve to the ice maker fill tube for any signs of restrictions and replace if necessary. WATER INLET VALVE: Check the water inlet valve for any restrictions. You will need to shut off the valve from the household water supply before you disconnect the inlet tubing. Some water inlet valves may have a screen to filter debris before it can enter the valve. If the screen is plugged, water flow will be restricted and the result will be small or layered ice cubes. Remove and clean the screen or replace the valve. If dirt has gotten into the valve it may not shut off completely and will continuously drip water into the ice maker fill tube and will eventually freeze up. Low household water pressure or a restriction at the manual shut off valve will also cause the water inlet valve to not shut off completely and create this same condition. Self piercing saddle valves are the most common shut off valve to cause this problem as the hole that is pierced in the water line is often too small and will more easily become restricted. The water inlet valve is operated by line voltage supplied through the ice maker control. Power is applied for approximately 7-9 seconds during the harvest cycle and energizes the solenoid on the valve to allow water to flow. You can check the solenoid for continuity with a multi-meter. On models with multiple solenoid inlet valves, you will need to determine which portion or portions of the valve are used for the ice maker. You can normally follow the inlet tubing from the ice maker back to the valve. Unplug the refrigerator and turn off the water supply to the valve before working with this part. (HOW TO TEST INLET VALVE: Inspect the filter screen where the supply line connects. Remove any debris or deposits that may have built up using a toothbrush or warm running water. If you cannot clear theclog, it will be necessary to replace the valve (the filter is not removable on most inlet valves). Test thewaterinletvalve for continuity using a multImeter. First, inspect the coil for an indication of it's ohm rating. If no information is printed on the coil, then use the range of 170 to 500 ohms. Set the multitester to the ohms setting X100 (if available, otherwise use the nearest ohm setting). Place a probe on each terminal. The multitester should display a reading that matches the coil's rating or if you don't know the rating then it should fall into the range of 170 to 500 ohms. If the water inlet valve does not pass this test, it should be replaced. If the inlet valve has two coils, test the second coil in the same way (note that they may not have the same ohm rating). The valve can also fail mechanically. So even if it passes the electrical test, it may still require replacement. If you have ruled out all other possibilities, go ahead and replace the valve. Check the tap valve.A bad tap valve-the little device that connects the ice maker's water supply tube to the water pipe-may cause the problem where the ice maker's supply tube connects to the water pipe. If necessary, replace the inlet valve and the tap valve. For the tap valve, use the type that requires you to drill a 1/4-inch hole (as opposed to the "self-piercing" type). You can buy anice maker connection kitand do this yourself, or call a repair person or plumber to install an inline water filter when replacing the valve. Lastly the ICE MAKER ASSEMBLY: If there are no ice buildup issues or suspected problems with the water supply, then you may have a problem with the ice maker control. The most common type of ice maker used in modern refrigerators is the heat release ice maker. The ice maker uses heat to release the ice cubes. If the water's route is blocked or the solenoid doesn't work-or if the bail wire is lifted-the ice maker won't make ice. (Also note that your home's water pressure may not be strong enough to serve an ice maker.) If you have a heat release or modular ice maker it will have a removable cover at the front. Behind the cover is a series of electrical test points that can be used to diagnose the ice maker. The unit can be manually operated by inserting an insulated jumper wire into test points "T" and "H" to initiate a "test harvest". On other ice makers jumper at points N & M (neutral to Motor) The jumper should be insulated 14 gauge solid wire that has the insulation stripped back about 3/4 of an inch on both ends, and bent into a "U" shape. When inserted into the test points for 5 to 10 seconds, the motor should start and the cycle will continue on its own. You may have to manually close the freezer door switch for this to operate. This test will simulate a real harvest cycle and will operate the ejector blades, shut off arm and the fill valve in the proper sequence, and will allow you to do a proper diagnosis. This is a live voltage test and should only be performed by a qualified person. If the motor does not start, you can verify that you have power to the ice maker at test points "L" and "N". If the ice maker is getting power and does not perform a cycle, then the module will need to be replaced On component mode ice makers the testing is done differently. Testing a thermostat in a component ice maker: The thermostat is located near the bottom ofthe support box. The thermostat is connected by two or three wires.Label the wire placement before disconnecting them. Remove thethermostat by loosening the clamp, by pushing back the retainerclips, or by removing the retaining screws. Test the thermostat forcontinuityusing amultitesterset to the ohms setting X1. Start by testing the thermostat whenit has come up to room temperature (about 20 minutes after removing it from the freezer). If the thermostat has two wires touch one probe to each wire. You should get a reading of infinity.Chill the thermostat in the freezer for about twenty minutes andretest. This time you should get a reading of zero (continuity). If the thermostat has three wires, number them 1, 2 and 3. Test combinations 1 & 2, 1 & 3and 2 & 3 and write down the results. Two of the combinations should yield a reading of infinity and one should yield a readingof zero. Now chill the thermostat in the freezer for about twenty minutes and retest. The combination that had a zero reading before, should now have a reading of infinity. One of the two other combinations should now yield a zero reading.If the thermostat fails this test, it should be replaced. Testing a modular ice maker 'sthermostatcan be tested and replaced individually. Test the thermostat forcontinuityusing amultitesterset to the ohms setting X1. Start by testing the thermostat when it is cold (10 degrees). Insert one probe into the hole labeled "T" and the other probe into the hole labeled "H". The meter should indicate zero resistance (continuity). After the ice maker has warmed up, repeat the test and this time the meter should indicate infiinity (no continuity).If the thermostat does not pass both tests, it should be replaced. God is the reason I give you free advice so God is good! 25508882-1qvynlgglfdkvwxnnfoef50k-2-0.jpg 25508882-1qvynlgglfdkvwxnnfoef50k-2-2.jpg 25508882-1qvynlgglfdkvwxnnfoef50k-2-5.jpg 25508882-1qvynlgglfdkvwxnnfoef50k-2-9.jpg
5/22/2015 9:52:51 PM • Beko... • Answered on May 22, 2015
0helpful
1answer

Freezer defrosting from top down why

Check ur cold control thermostat, ur thermistors in both fridge and freezer ( they should be checked for both ohms and for amount of current being put out as per ur model ), ur air flow vent from freezer to fridge.( to make sure it opens and closes without any restrictions) On thermistors check for A close circuit and amount of ohms not just an Ohm reading. As per ur model. Most should atleast show 1200 ohms. Also Check door seals for leakage. Evaporator coils Poor cooling is often the result of a heavy frost build-up on the evaporator coils. You can't see these coils without removing a panel on the inside of your freezer. A sure sign that there is a build-up is the presence of any frost or ice build-up on the inside walls, floor, or ceiling of the freezer. Such a frost build-up usually indicates a problem in the self-defrosting system or damaged door gaskets. If one of the components in the self-defrosting system fails, the refrigerator continues to try to cool. Eventually, though, so much frost builds up on the evaporator coils that the circulating fan can't draw air over the coils. There may still be a small amount of cooling because the coils are icy, but with no air flow over the coils, cooling in the refrigerator compartment is quite limited. FAN check to see if it is operating or restricted A fan that is not blowing or restricted will not circulate the cold air properly. Often, the first thing that folks do when their refrigerator starts to feel warm is turn both controls on the coldest settings.This is exactly the WRONG thing to do.Turning the cold control to the coldest settingwillkeep the compressor running longer and make lots of cold air. But turning the air door to the coldest settingclosesthe airway to the food section. Lots of cold air is made, but most of it stays in the freezer section, and the food section actually getswarmer. Condenser Self-defrosting refrigerators all have a set of coils and a cooling fan, usually under the refrigerator, that need to be cleaned regularly. If these coils get coated with dust, dirt or lint, the refrigerator may not cool properly. The coils may appear to be a thin, black, wide radiator-like device behind the lower kick-panel. To clean them, disconnect the refrigerator from the power source, use a refrigerator condenser brush and your vacuum cleaner to clean the coils of any lint, pet hair, etc. You may not be able to get to all of the condenser from the front, it may be necessary to clean the remainder of the condenser from the rear of the refrigerator. May also need to check the defrost timer, u can get by and test manually by placing a small screw driver into the tiny slot or hole underneath the timer and turn slowly clockwise till u hear 1 click. this will engage ur defrost cycle in about 15 minutes u should be able to come back and feel the heat in freezer as it melts the ice providing ur terminator is not bad? Another way to test it is with a multi meter. Remove timer it from fridge and you will see 4 prongs numbered 2,1,4,3 in that order. Place ur meter prong on prong 1 & 3 (if your fridge has a capacitor wired in series with the windings, then u check for micro fares rather than OHMS) If u cannot confirm this test, still try the next. Take ur meter prong and connect to prong 1 & 4, it should read resistance or ohms ( closed) now remove prongs and place on prong 1 & 2, this should now read infinity or open (no ohms) now take a small screwdriver place it in the tiny hole or slot under the timer. Turn it clockwise slowly till u hear 1 click. Now ur 1& 2 should read closed ( showing ohms or resistance) now place meter prongs on 1 & 4 and you it should now show open ( or no resistance - no ohms) this is how u know ur timer is good, Remember when testing for ohms ADJUST meter to use a high ohms rating in the thousands as the resistance is very high in OHMS. And adjusting to low ohms rating may give a false reading or not show the proper resistance.. THE COMPRESSOR: If you hear a clicking sound coming from the back of your refrigerator/freezer, then the problem is most likely the compressor, relay and or capacitor is overheating or not getting proper power and will not start.The compressor is the component on your refrigerator that allows your refrigerator to cool. If this component is not working properly your refrigerator will stop cooling. Most of the time the compressor is not the component that has failed. To check ur compressor with multi meter: Disconnect and remove the relay and capacitor from compressor, some located next to compressor in a casing. You wills see 3 prongs coming out of compressor. 1 goes to ur srtart winding, 1 goes to ur run winding and the center goes to ur ground. Place ur meter connector or prong on the start prong and the other on the ground (center prong) take note of the reading in OHMS for example 5 ohms. Next place meter prong on run prong and the center ground prong agin. Take note of the reading in OHMS. Example 4 ohms Next place meter prong on the start prong and the other on the run prong, now take note of the reading example 9 ohms. Now match the total of this ohms test with the total of ur two separate test. 9 ohms, if they match ur ok give or take 5 percent plus or minus. One more test to make to test of there is a short in compressor attach meter prong to ground prong and rub the other end of meter prong to metal ( scrape the metal clean of paint and test on metal surface not painted surface. If it shows continuity or ohms , u have a short in ur compressor. It should show infinity Lastly you should also check ur THERMISTORS in the freezer and fridge section for continuity OHMS and for amount of OHMS current being put out. In most models around 13000 ( give or take 150 ohms) ohms is required. Read more: http://removeandreplace.com/2013/10/31/fix-refrigerator-freezer-wont-cool-freeze/#ixzz3WDEo5NDJ REMEMBER GOD IS THE REASON FOR GOOD ADVICE" Refrigerator Is Not Cooling What To Check And How To Fix 25525456-1qvynlgglfdkvwxnnfoef50k-2-0.jpg 25525456-1qvynlgglfdkvwxnnfoef50k-2-2.jpg 25525456-1qvynlgglfdkvwxnnfoef50k-2-5.jpg 25525456-1qvynlgglfdkvwxnnfoef50k-2-9.jpg 25525456-1qvynlgglfdkvwxnnfoef50k-2-14.jpg
5/22/2015 9:50:18 PM • Beko... • Answered on May 22, 2015
0helpful
1answer

Removed water filter to wash and cannot remember how to re-fit. Diagram in manual doesn't clearly show order to put parts back together.

Hi there, can you please post some pics of all the filter parts that need to be put back together to get an idea what type of filter it is ?? Thanks G Man
4/28/2015 5:47:30 AM • Beko TLDA662 • Answered on Apr 28, 2015
0helpful
1answer

Too much noise with my beko unit (specially in the evening) is this normal??

Remember during the day time.There is a lot outside noise that drowns out the noise of refrigerator. And in the evening there's less background noise to mask it.
4/18/2015 1:33:09 AM • Beko... • Answered on Apr 18, 2015
0helpful
1answer

Ive just defrosted my fridge freezer and it wont come on its ice free fridge but started to build up ice which left my fridge damp at the bottom when ive defrosted it , so when i tried switching it on

Fridge freezing up- and no fan or air circulation: AT TIMES The fan usually stops working due to ice obstruction when the defrost terminator has gone out and u get ice build up? u can check the terminator with a multi meter for continuity but do not check at room temperature. stick the terminator in cup of ice water for 20 minutes then check it for continuity, should be closed when cold and open at room temperature. May also need to check the defrost timer, u can get by and test manually by placing a small screw driver into the tiny slot or hole underneath the timer and turn slowly clockwise till u hear 1 click. this will engage ur defrost cycle in about 15 minutes u should be able to come back and feel the heat in freezer as it melts the ice providing ur terminator is not bad? Another way to test it is with a multi meter. Remove timer it from fridge and you will see 4 prongs numbered 2,1,4,3 in that order. Place ur meter prong on prong 1 & 3 (if your fridge has a capacitor wired in series with the windings, then u check for micro fares rather than OHMS) If u cannot confirm this test, still try the next. Take ur meter prong and connect to prong 1 & 4, it should read resistance or ohms ( closed) now remove prongs and place on prong 1 & 2, this should now read infinity or open (no ohms) now take a small screwdriver place it in the tiny hole or slot under the timer. Turn it clockwise slowly till u hear 1 click. Now ur 1& 2 should read closed ( showing ohms or resistance) now place meter prongs on 1 & 4 and you it should now show open ( or no resistance - no ohms) this is how u know ur timer is good, Remember when testing for ohms ADJUST meter to use a high ohms rating in the thousands as the resistance is very high in OHMS. And adjusting to low ohms rating may give a false reading or not show the proper resistance.. Another item to check with a meter is the heating element itself. Located under the evaporator coils. It should show continuity or resistance OHMS WHEN TESTED AT BOTH ENDS OF THE PRONGS . Lastly check the cold control thermostat with a meter for both OHMS and volts ( VOLTS is a live test with fridge plugged in so be careful) It must show 110 volts. An open or thermostat that reads infinity will not allow the proper cooling and defrosting cycles to operate and may in fact stop anything from happening as if there is no power to the unit? ALSO CHECK THE AIR FLOW VENT SYSTEM
4/4/2015 11:13:48 PM • Beko... • Answered on Apr 04, 2015
0helpful
1answer

I have a beko fridge freezer. The fridge freezes up on lowest settings. The condenser tray gets full of water. I have replaced the thermostat (circit board) and defrosted but it still ices up. A even

Fridge freezing up- and no fan or air circulation: AT TIMES The fan usually stops working due to ice obstruction when the defrost terminator has gone out and u get ice build up? u can check the terminator with a multi meter for continuity but do not check at room temperature. stick the terminator in cup of ice water for 20 minutes then check it for continuity, should be closed when cold and open at room temperature. May also need to check the defrost timer, u can get by and test manually by placing a small screw driver into the tiny slot or hole underneath the timer and turn slowly clockwise till u hear 1 click. this will engage ur defrost cycle in about 15 minutes u should be able to come back and feel the heat in freezer as it melts the ice providing ur terminator is not bad? Another way to test it is with a multi meter. Remove timer it from fridge and you will see 4 prongs numbered 2,1,4,3 in that order. Place ur meter prong on prong 1 & 3 (if your fridge has a capacitor wired in series with the windings, then u check for micro fares rather than OHMS) If u cannot confirm this test, still try the next. Take ur meter prong and connect to prong 1 & 4, it should read resistance or ohms ( closed) now remove prongs and place on prong 1 & 2, this should now read infinity or open (no ohms) now take a small screwdriver place it in the tiny hole or slot under the timer. Turn it clockwise slowly till u hear 1 click. Now ur 1& 2 should read closed ( showing ohms or resistance) now place meter prongs on 1 & 4 and you it should now show open ( or no resistance - no ohms) this is how u know ur timer is good, Remember when testing for ohms ADJUST meter to use a high ohms rating in the thousands as the resistance is very high in OHMS. And adjusting to low ohms rating may give a false reading or not show the proper resistance.. Another item to check with a meter is the heating element itself. Located under the evaporator coils. It should show continuity or resistance OHMS WHEN TESTED AT BOTH ENDS OF THE PRONGS . Lastly check the cold control thermostat with a meter for both OHMS and volts ( VOLTS is a live test with fridge plugged in so be careful) It must show 110 volts. An open or thermostat that reads infinity will not allow the proper cooling and defrosting cycles to operate and may in fact stop anything from happening as if there is no power to the unit? ALSO CHECK THE AIR FLOW VENT SYSTEM
4/4/2015 9:40:11 PM • Beko... • Answered on Apr 04, 2015
0helpful
1answer

Oven not heating but light and fan coming on

check the element with a multi meter for continuity.
3/21/2015 7:33:33 PM • Beko... • Answered on Mar 21, 2015
0helpful
1answer

Gnev120w Made a noise, now not freezing.

the fan only controls air circulation. not the function of the motor. sounds like ur fridge is stuck in the defrost mode? check ur cold control thermostat with a multi meter for continuity. the fan does not run while in defrost mode, u can manually check ur defrost timer in the fridge by sticking a small screwdriver into the hole underneath it, and turn clockwise till u hear a click u should hear the fan and compressor come on if not turn 1 more click?
3/21/2015 7:02:36 PM • Beko... • Answered on Mar 21, 2015
0helpful
1answer

Hi. Why has my Beko fridge freezer ceased freezing. Fan & light still function.

compressor is running? u can hear it? may have a freon leak? or check the defrost timer or cold control thermostat, some freezers have a freezer thermistor may have gone bad can check all with a multi meter
3/12/2015 8:35:47 PM • Beko... • Answered on Mar 12, 2015
0helpful
1answer

DOES THE BEKO CDA653FS HAVE A FAST FREEZE BUTTON

Probably not. but check Owner's manual no manual? you'll need it some time later anyway try http://www.manualslib.com/
3/8/2015 10:13:51 AM • Beko... • Answered on Mar 08, 2015
0helpful
1answer

Ice machine not working in my new beko fridge GNE60520 DX, does anyone know how to rectify this problem

Is the water hooked up? New fridges don't usually come with the ice maker hookup it's extra, and most of the time they don't tell you that when you buy it, hope this helps?
3/3/2015 1:54:17 PM • Beko... • Answered on Mar 03, 2015
Not finding what you are looking for?
Beko Logo

125 questions posted

Ask a Question

Usually answered in minutes!

Top Beko Refrigerators Experts

Cindy Wells

Level 3 Expert

6688 Answers

Brad Brown

Level 3 Expert

19187 Answers

Ngoro

Level 3 Expert

3523 Answers

Are you a Beko Refrigerator Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...