Amcor Dehumidifiers - Page 2 - Recent Questions, Troubleshooting & Support

0answers
0answers
0helpful
1answer

Where, in the UK, can I obtain Amcor replacement parts?

the thermal break is there for a reason, the motor has overheated, if this was due to a towel or other item covering the unit great remove the the obstruction and replace the thermal break. however the major cause is that the bearings have dried up on the motor and it has started to seize, which means replacement.
10/10/2013 10:21:36 AM • Amcor MD250... • Answered on Oct 10, 2013
0answers
0helpful
1answer

AMB 10000E Red light on the right of the control screen is on. What does this mean?

i have this problem too...red light, no explaination. did you find a solution?
7/13/2013 2:23:52 PM • Amcor AL-10000E... • Answered on Jul 13, 2013
0helpful
2answers

Amcor Dehumidifer TC120 - Circuit Board Required

It is not your relay. Mine did the same and the problem is the resistor that drive it goes short so the relay clatters as the circuit is trying to control it. The actual fault is the 78p153sp driver. You can change the transistor, a pnp will do the trick but the driver is dead. I'm currently looking for this IC and they're hard to find, cheap Chinese tat. So instead I'll likely fit a temp sensor that detects when the cooling coils reach about 4deg and switch the fridge off because shorting the relay will just cause the cooling to stay on and you'll get ice, it needs to cool, collect moisture, switch off, warm up and dump the moisture...crude but it works. This unit is worth saving.
3/9/2013 7:18:46 PM • Amcor... • Answered on Mar 09, 2013
0answers
0answers
0helpful
2answers

Stopped collecting water after five years operation.

Have you emptied the water out of it?
8/16/2012 1:44:57 PM • Amcor... • Answered on Aug 16, 2012
0helpful
1answer

Amcor des 80 not heating

I've had my DES80 pack in twice with the same symptoms. (I was using it 24/7 for about 8 years, so that was pretty good going I reckon!). First failure was a fractured heating element termination - easily repaired at no cost. Second time was the thermal fuse on the same sub- assembly - only pence to fix. The problem is just how far you have to tear it down to get to this assembly, but you need no more than a long cross- point screwdriver, and some patience. I have photos of all the stages of disassembly & reassembly, just Email me [email protected]. Cheers, David
11/25/2011 6:44:06 PM • Amcor... • Answered on Nov 25, 2011
Not finding what you are looking for?
Amcor Logo

87 questions posted

Ask a Question

Usually answered in minutes!

Top Amcor Dehumidifiers Experts

ZJ Limited
ZJ Limited

Level 3 Expert

17989 Answers

Brad Brown

Level 3 Expert

19187 Answers

ADMIN Andrew
ADMIN Andrew

Level 3 Expert

66931 Answers

Are you an Amcor Dehumidifier Expert? Answer questions, earn points and help others