WASHER WILL NOT RINSE:
If your washer doesn't go through the washer rinse cycle, the most likely cause is the water valve. What happens is thewater valvewill stop letting cold water into the washer; therefore, once the washer gets to rinse it will either stop or not do anything during the whole rinse cycle.
This is because when you selected your water temperature, youmay haveselected warm/cold or hot/cold. The hot water came in and you didn't notice any problems. When it got to rinse, the cold water the cold water won't come in. Therefore, the washer does nothing.
Theitem to check would be your water inlet valve. Check it for continuity with a multi meter it should show Ohms or a closed circuit. To test it when water is overflowing unplug the unit and see if it still overflows or continues to fill. If it stops when unplugged. Then it is not a water inlet problem but an electrical signal problem going tourwater inlet valve. Possibly from the panel or board. You can also do a live volt test to see if it is getting the full 120 current, but be sure to unplug unit before testing as this is a live test.
Another test u can do to check thewaterinletvalve,first cut the water off and remove the hoses off the back of the washer. Then one at a time point the hoses inside the washer tub and turn the water back on. If you don't have good water pressure, turn the water back off and remove the strainer that should be in one end of the hose. Inspect the strainer to see if it is stopped up, clean it and reinstall it. Now repeat this test. If you have good water pressure now, reinstall hose and your problem is fixed.
.
If you still don't have good water pressure, the problem is in your house plumbing and you need to call a plumber. If you had good water pressure the first time you performed the test, the water valve is bad and needs replacing.

If you still don't have good water pressure, the problem is in your house plumbing and you need to call a plumber. If you had good water pressure the first time you performed the test, the water valve is bad and needs replacing.
TIMER
If your washer doesn't go through the washer rinse cycle the timer may be the problem. Sometimes the timer gets stuck in the middle of the cycle or won't turn at all. If the washer runs,but the timer doesn't turn, the timer is bad and needs replacing.
Do you have anti-flood hoses leading to the machine. If you do there is probably a loose tube in the back causing a small leak. When the hoses detect that water is still flowing after a certain amount of time due to the leak it shuts down and causes the machine to turn off during the rinse/spin cycle
By the way my advice is freecuzGod is good!








inlet voltage test waterinlet valve-undefined-undefined-0.jpg

inlet dirty water inlet screen-undefined-undefined-2.jpg

inlet how2clean inletvalvewest_washer4-undefined-undefined-5.jpg

inlet testing washerwater inlet valve-undefined-undefined-9.jpg

Admiral Washing... | Answered on Mar 16, 2020


What is the model number of the unit?

Admiral Washing... | Answered on Sep 24, 2019


Do you check to see if it's belt driven? If it is your belt might have come off or needs to be replaced

Admiral Washing... | Answered on Jun 13, 2019


Belt slipping or transmission clutch bearings are on the way out.

Admiral Washing... | Answered on May 03, 2019


Timer or control board issue most likely. If it has a start button, make sure it’s not stuck

Admiral Washing... | Answered on May 01, 2019


The seal has cracked and will need to be replaced. Part of it is in the drive block attached to the basket and is probably your failure. All you need to remove is the maytag tool and a strong arm.

Admiral AAV7000A | Answered on May 01, 2019


if its broken then yes

Admiral Washing... | Answered on May 01, 2019


Have you tested the voltage at the dryer terminal block?
Left stud to the rht stud should read 240 vac.
both outside to center should be 120vac.
Follow the path of electricity on the diagram.
thermals fuse open? Wires cut to door switch?
Being that the timer drive motor is humming ,you are getting at least 120vac to the dryer ,but possible not 240vac.
Model# ??

Admiral Dryers | Answered on Apr 28, 2019


I have no idea what dryer your talking about due to the fact that there is no model number posted!
most dryers have two thermal fuses which can be found in the diagram.
The timer can be at fault with a contact not closing.
Diagram again!
Motor switch could be at fault, closes heat circuit after motor starts. Diagram again!
dDont throw parts at it until you verify the cause, you have spent enough already.

Admiral Dryers | Answered on Apr 28, 2019


Check to see if there is a build up of dust/lint/grunge on the heat exchange pipes on the back or around the pump/motor. Vacuum it off. Check to hear if the motor is running. You may need to have coolant added but first look for leaks.

Admiral... | Answered on Apr 28, 2019


WHY DON'T YOU JUST TRY IT WE HAVE NO CLUE HERE

Admiral Washing... | Answered on Apr 07, 2019

Not finding what you are looking for?

Ask a Question

Usually answered in minutes!

Top Admiral Experts

john h

Level 3 Expert

23424 Answers

Bill Boyd

Level 3 Expert

53814 Answers

Tom Chichester

Level 3 Expert

56004 Answers

Are you an Admiral Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...