Questions & Answers for: wiring older dometic circuit board

Question about Rooftop RV Air Conditioner

1 Answer

Dometic Rooftop Air Conditioner The compresser for the A/C unit will come on.When you turn on the fan at the thermostat it blows the 3amp fuse in the A/C circuit board.Is the circuit board bad or is ...

Ad

...circuit board. (between 1993-1996 dometic used a yellow epoxy filled circuit board that went out pretty quickly) if you have the yellow filled circuit board rather than the green one it is most likly ...

Ad

Question about NDR 1292 Refrigerator

1 Answer

...unit. If it cools you probably have either a short, or the main circuit board is bad. (in 1993-1996 Dometic used a yellow epoxyed circuit board that almost allways went out at about 2-5 years of

dometic RM 2652. On electric the heater stays hot for a while and cuts off and won't come back on. Can unplug for a while then plug back up and the heater will stay hot for a while then cut off again.

Question about WA3210 Compact Refrigerator

1 Answer

Dometic rm4223 wont run at all The refrigerator is a 3-way unit. I have power to the plug, but I plugged the unit in and turned just the electrical switch on only and left it on for 12 hours, the ...

Question about 57915531 Air Conditioner

1 Answer

Dometic 15000btu first start amps at 8 up to 15 then will go to 30 trips breaker coil clean all wires tight unit 2 years old. Contact Dometic due to part defect. Circuit board

Question about Rooftop RV Air Conditioner

1 Answer

...continues to run until unplugged at circuit board box. Definately mis wired. All you have to do is s put a circuit breaker where the two wires come together. Hopefully in the psnel.. Good Luc, ...

Question about Rooftop RV Air Conditioner

1 Answer

...Dometic manual I have doesn't say anything about trouble shooting the board. Is it likely that I have a board failure? I didn't find any burned spots on the board. Previously, I had intermittent ...

Question about RM2652 Refrigerator

1 Answer

Dometic service manual says: 1. No operation - no panel lights: DC Volts Fuse Wiring Upper Circuit Board Lower Circuit Board http://www.gasrefrigeration.net/dom_techdata/26121_2852SM.PDF I would start

older units have the limit mounted on the heat exchanger straight in front as u look at unit. try taping on unit . newer units are on a circuit board . just for the heck of it  unhook the green t

Not finding what you are looking for?

Ask a Question

Usually answered in minutes!

Top Heating & Cooling Experts

Paul Carew

Level 3 Expert

3808 Answers

john h

Level 3 Expert

29494 Answers

Brad Brown

Level 3 Expert

19187 Answers

Are you a Heating & Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...