Questions & Answers for: RTO terminal

Question about 110cc Basic Manual ATV # ATD-125C

2 Answers

...to starter. That will crank up the starter. just use a screwdriver and wedge it between the two big terminals on the relay to make contact to each other and the motor will turn over. You can also run ...

Ad

Question about Intermatic T104R3 Timer Switch 220V - Metal Enclosure

2 Answers

...when it does things like that. The 240 volt clock motor is internally connected at the factory to terminals 1 and 3. That means that one of the incoming (line) 240 volt wires (pick one) _must_ be ...

Ad

Question about Intermatic T101M Timer Mechanism Only 110V

1 Answer

...link: http://waterheatertimer.org/How-to-wire-T104-Intermatic-timer.html#T101 Hot wire goes to terminal 1 Neutral to terminal A Black wire to pump goes to terminal 2 White wire to pump goes to ...

Question about Idec Rte-p1ad24 24vac/dv Electronic Timer

1 Answer

cant get the timer to power up, I know incoming power is on 2 and 7 .do i need to jump to other terminals? RTE-p1ad is 24-volt AC 8-pin on-delay timer. Manual for RTE-P1 & RTE-P2 ...

Question about Intermatic T106M Timer Mechanism Only for T106R

2 Answers

...do I connect my 2 speed pool motor? 1) You might need a different timer. 240Volt T106 has one NO terminal and one NC terminal. ...

Question about Intermatic T106M Timer Mechanism Only for T106R

1 Answer

...For example Line wires are 240Volt, and there is 1 black wire and 1 white Black connects to terminal 1 White connects to terminal 2 Add a jumper wire (short piece of same-gauge wire) from ...

Question about Intermatic T106M Timer Mechanism Only for T106R

1 Answer

...motor is a 220 v 3/4 HP it worked on the intermatic. any suggestions? Necessary for you to match up terminal numbering with actual numbers for each timer. Information below is for 240volt timer ...

Question about Sole F80 Treadmill

1 Answer

my fans on my brand new sole f80 dont come on 1( test the voltage at the terminal of the FAN, if there are the FAN is faulty.2( test the voltage at the terminal , if there are NOT TEST why NOT coming ...

I have a G6A-3E heater. didn't work untill I cleaned the terminals on the t,stat It works but shuts off befor the water is hot! after allowing the mach. to cool it can be turned back on & runs

...please see the video attached and proceed according. However you must test the power voltage input terminal motor use the multimeter, see my personal TIPS for Motor HELP.if there ARE the motor is ...

Not finding what you are looking for?

Ask a Question

Usually answered in minutes!

Top RTO Cycling Experts

ADMIN Andrew
ADMIN Andrew

Level 3 Expert

66931 Answers

Kardoc

Level 3 Expert

7503 Answers

Tony Parsons
Tony Parsons

Level 3 Expert

6405 Answers

Are you a RTO Cycling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...