Questions & Answers for: Minolta no temperature control

Question about magicolor 2200 DeskLaser Printer

1 Answer

...control the electricity flow to the fuser lamps. One of these has likely gone bad. As an explanation, these thermostats work just like the thermostat for a typical home central heating system. They ...

Ad

Question about magicolor 2200 DeskLaser Printer

1 Answer

...control the electricity flow to the fuser lamps, has likely gone bad. If you are feeling generous to the money pit governed by Konica-Minolta, you'll need to replace the fuser unit. Otherwise, you'll ...

Ad

Question about EP4000/5000 CS/PRO Copier

2 Answers

...temperature control. - Check the connector of the fixing film unit. - Replace the fixing film unit. - Replace the DC controller PCB. 0001 Abnormally high temperature (detected by sub thermistor) The ...

Question about bizhub 350 Black and White Copier

1 Answer

...the service manual that deals with this code: Thermistor /1 (TH1) detects a low temperature when a specified period of time elapses after the fusing heater lamp is turned ON for the fusing ON

Question about DI2510 Black and White Copier

1 Answer

...Temperature Failure (Sub Heater) Sir/Mam, First ensure that the right side cover is closed correctly. Check that the two latches that are on the door are not broken especially the rear one. Then fine ...

Question about DI2510 Black and White Copier

1 Answer

...Temperature Failure (Sub Heater) pleace help me Sir/Mam, First ensure that the right side cover is closed correctly. Check that the two latches that are on the door are not broken especially the rear ...

Question about bizhub 350 Black and White Copier

1 Answer

...temperature when a specified period of time elapses after the fusing heater lamp is turned ON for the fusing ON control.If the fusing unit is OK try to reset: Turn off the copier.Press and keep ...

Question about bizhub 350 Black and White Copier

1 Answer

...temperature of 190°C is detected in ready mode after printing finished. Remedy 1. Turn on the power again, and verify the fuser warms up. If it does not, see step 4. 2. Check the contact between ...

Not finding what you are looking for?

Ask a Question

Usually answered in minutes!

Top Minolta Office Equipment and Supply Experts

Norman Weimar
Norman Weimar

Level 3 Expert

7035 Answers

ZJ Limited
ZJ Limited

Level 3 Expert

17989 Answers

Daniel Blask
Daniel Blask

Level 2 Expert

232 Answers

Are you a Minolta Office Equipment and Supply Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...