...td sensor location we are getting an sc385 error from our aficio color 6513 and from what i have discovered, the id sensor and the td sensor may need to be cleaned. where is the id sensor located? is ...

Ad

Question about 6513 Copier

1 Answer

...TD sensor information (K) - Timing - When communicating with TD sensors, during printing process, or process control self-check - Condition - TD sensor output exceeds 4.5V or drops below 0.5V. ? Poor ...

Ad

Question about Aficio 1515MF All-In-One Laser Printer

2 Answers

TD sensor error The BICU detects the TD sensor outputting abnormal voltage (less than 0.2 V or more than 4.0 V) 10 times consecutively. ? Defective TD sensor ? Loose connection of the PCU you may need

Question about Aficio 1013F Copier

1 Answer

...TD sensor error test value abnormal the TD sensor output voltage is less than 0.5v or more than 5.0v after 10 consecutive times during copying the possible cause willbe TD sensor defective,TD sensor ...

Question about Aficio 2015 Copier

1 Answer

sc 390 SC 390 TD sensor error The TD sensor outputs less than 0.5V or more than 4.0V 10 times consecutively during copying. ? TD sensor abnormal ? Poor connection of the PCU

Question about Aficio 2015 Copier

1 Answer

...TD sensor error -Definition- [B] The TD sensor outputs less than 0.5V or more than 4.0V 10 times consecutively during copying. - Possible causes - · TD sensor abnormal · Poor ...

Question about Aficio 1035 Copier

1 Answer

...TD sensor defective TD sensor not connected or disconnected damage Poor connection between the TD sensor and IO board IO board defective Toner supply defective * Insufficient toner in developing ...

...TD sensor disconnected • Harness between TD sensor and PCU defective • Defective TD sensor, replace the PCU Note: The TD sensor cannot be replaced independently. The PCU must be replaced if the TD ...

TD sensor error black PCU possible cause: • TD sensor harness disconnected, loose, defective • A drawer connector (located on the rear of a development unit) disconnected, loose, defective • TD sensor

...TD sensor (Vt high) error 1: C • The Vt value of the black, magenta, cyan, or yellow TD sensor exceeds the specified value (default: 4.7V) with SP3-020-002 for twenty counts. • The [Vt - Vtref] value ...

Not finding what you are looking for?

Ask a Question

Usually answered in minutes!

Top Office Equipment & Supplies Experts

k24674

Level 3 Expert

8093 Answers

Brad Brown

Level 3 Expert

19187 Answers

ADMIN Andrew
ADMIN Andrew

Level 3 Expert

66855 Answers

Are you an Office Equipment & Supplies Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...