...SC 990 is a communication error between the BICU board and the IOB, check the connections, cables, switches, sensors of the IOB and make sure that has a good connection to the BICU. Hi, does the ...
...sc 990 apears and iwant to increase the fils memory hello usama you need to delet some files the software performs an unexpected function if you want to increase memory you need HDD more than 40 GB ...
...40 minutes and check if the error still appears. If you see he error still appearing then try and rest it using the following reset method-- To reset the SC code by entering SP5810 and select 1. Now ...
Question about Aficio 250 Copier
...SC 320 - Polygon motor error.The polygon motor does not reach its operating speed within 10 sec. after the polygon motor on signal,or the lock signal is not detected for more than 40 ms continuosly ...
sc 542 Description Fusing temperature warm-up error The fusing temperature does not reach the fusing standby temperature of 45C (113F) within 9 seconds [for the B003/B006 (35 cpm)]/14 seconds [for the
...SC: 320 Error in Ricoh 161L SC320 is the laser polygon mirror motor error. It does not reach the right speed. repair or replace laser unit. 320 show when polygon motor in laser unit move slow or cant ...