...getting a error message, you will more than likely have to place a service call to have the fuser
...either disassembling the fuser and replacing the thermistor ( if you can find one) or replacing the fuser assembly. so i would suggest that take it to nearest service centre of lexmark. best of ...
920.07 code on a t642 a 920 error means your fuser is under temperature at standby. you should replace the thermistor it cycles the fuser on and off to maintain these temps
...fuser. the thermistor has been comprimized. the reason the printer slows down is the regulation of the heat has slowed and the fuser is not heating fast enough to keep up with the demand. changing ...
...replace the actual fuser assembly. unfortunately you can't just remove/clear the error. see picture attached as this is what the fuser looks like after you replace it let me know if you still receive ...
eror 202 The left "trip" switch on the back side of the printer (fuser unit) is stuck or bad. Unplug from the fuser and test. Will need to replace unit or replace fuser.
...to do? This error indicated that the fuser assembly in the printer has failed and will need to be replaced. The fuser is the part of the printer that heats up and bonds or "fuses" the toner to the ...
...fuser has gone out. Depending on how old your printer is, the fuser could need either rebuilt or
fuser. I used to have this problem with other Lexmark models and was able to replace the thermister itself. The thermister is located on the top cover of the fuser. If you have a real Radio Shack near
Question about T642 Laser Printer
displays 922.02 service fuser error when the printer was never used? It could be the connector to the fuser from the LVPS is not connected properly. It could also be the Thermistor on the fuser is bad