Questions & Answers for: pool heater lights flames coming

Question about Laars Lt 400,000 Btu Heater

2 Answers

...sure where to go from here. Any suggestions my guess is you are a pool guy so im not going to awser this one heater comes on for about 2 minutes then service light comes on and so does the ags ...

Ad

Question about 266K to 399K BTU Swimming Pool Natural Gas Heater ()

1 Answer

Pool Natural Gas Heater keeps failing and giving me a ROL and SPR code. The thing is a little over a year old and only been used 1x last winter (we live in Florida). Cannot find anything in the manual

Ad

Question about LXi250 Natural Gas IID Digital Low NOx Heater - Adjustable For Up To 10,000ft Altitude

2 Answers

...lights on board. Hi, That is an ignition failure code... meaning that it tried to light unsuccessfully three times.... Check to see if the ignitor is glowing... then check the gas valve to see if ...

Question about H-series Electronic Gas Pool Heater H400

1 Answer

...pool/spa combo. The code reads "00" in the heater window and does not change when the unit controlls are pressed. I have an aqualink controller indoor that turns the unit on it has seperate ...

Question about H-series Electronic Gas Pool Heater H400

3 Answers

heater Same type of problem. If you can't hear the relay click when you turn it on......your control board is faulty even if all the lights on ie power, flow, heat... The power for the igniter and gas

Question about Hayward H250 250k BTU Millivolt Pool Heater - Propane

1 Answer

...pool heater. These systems were designed for use with two temperature thermostats so that the heater could be used as both a spa heater and a pool heater just by switching water valves and switching ...

Question about Lite 2 Natural Gas Pilot Light Heater

2 Answers

...heater know that the pilot light has been lit and it's okay to open the main valve. Here's a picture of the Jandy Lite 2 flame sensor in use. It's the glowing red rod on the right side of the flames. ...

Question about Hayward H250 250k BTU Millivolt Pool Heater - Propane

0 Answer

pool heater will not light I cleaned the burners, igniter, and flame sensor. The igniter does glow. The fan comes on. Gas flows. The burners will not light. After 3 tries, I get 1F code. Why won't

...pool heater lights but shutdown with FL2 error tested resistance/voltage and ok. What else could it be? check safety circuit pressure switch to see if full 24 volts on both sides if not bad pressure ...

Question about Pressure Switch 3902 Swimming Pool Heater Millivolt

0 Answer

pool heater I have a raypak 255wg-n pool heater the pilot light is lite but having trouble getting unit to fire. I originally thought that it was the pressure switch acting up so I bypassed it and the

Not finding what you are looking for?

Ask a Question

Usually answered in minutes!

Top Pool & Spa Experts

Jay Finke
Jay Finke

Level 3 Expert

1397 Answers

john h

Level 3 Expert

29494 Answers

David Spradling
David Spradling

Level 3 Expert

13524 Answers

Are you a Pool & Spa Expert? Answer questions, earn points and help others

Answer questions