...Pentair Manufacturer warranty. The issue you are describing remains a problem with the electronics. Since you are not getting any alarm codes, there may be in issue in the wiring or you may have a ...
Question about Variable Speed 230v IntelliFlo Pump
describe how to wire a 230v SVRS intelliflo from a 2 pole 120v time clock see side of pump wiring schematic low vs high voltage
Question about IntelliFlo VS-3050 & VS+SVRS Variable Speed Pump -
pentair pump alarm says overcurrent.How do I fix or reset to get my pump running once again.pump was running fine ????? check voltage and wiring if ok maybe motor overheating and drawing too much ...
Question about IntelliFlo VS-3050 & VS+SVRS Variable Speed Pump -
wiring diagram for pentair intelliflo pool pump How to connect the power to the pump see side of motor for voltage wiring
Question about IntelliFlo VS-3050 & VS+SVRS Variable Speed Pump -
Have the intellipro vs svrs pump and the breaker keeps tripping after about 30 seconds. just had a big rain storm as well. any ideas on whats wrong check the back of the pump motor wires are probably ...
Question about Minimax NT Heater
board control or clean it up. It may be better than ever. Pentair 011018 IntelliFlo Variable Speed High Performance Pool Pump Hayward AQR15 Goldline AquaRite Electronic Salt Pool Chlorinator Control..
Question about IntelliFlo VS-3050 & VS+SVRS Variable Speed Pump -
why does my intelliflo pool pump on/off switch shows yellow led instead of green make sure wiring correct for 120 volt vs 220 volt if ok check intake union see if leak
Question about IntelliFlo VS-3050 & VS+SVRS Variable Speed Pump -
overcurrent alarm intelliflo veriable spee check incomming voltage was pump wired correctly see diagram on side of motor
Usually answered in minutes!
1,045 Questions
774 Questions
337 Questions
287 Questions