LOW B OCP/OVP (Overcurrent/over voltage). Possible causes: +5 line is overloaded. (A, B boards), +5 line is shorted. (A, B boards). Symptoms of the problem: No picture. also check out this sony recall
...LOW B OCP/OVP (Overcurrent/over voltage)...+5V Line Overloaded or shorted on the A or B board. can I repace these boards or fix them do you know a price,part or what they look like so I can get a ...
Question about Grand WEGA KDF-55WF655 36" Rear Projection HDTV
...pattern: 6 times, Diagnosis: LOW B OCP/OVP (Overcurrent/over voltage). Possible causes: +5 line is overloaded. (A, B boards), +5 line is shorted. (A, B boards). Symptoms of the problem: No
Question about Grand WEGA KDF-55WF655 36" Rear Projection HDTV
...LOW B OCP/OVP (Overcurrent/over voltage). Possible causes: +5 line is overloaded. (A, B boards), +5 line is shorted. (A, B boards). Symptoms of the problem: No picture. but I dont know how to fix ...
...Low B+ OCP/OVP SOLUTION: Replaced Flyback transformer. It had no rings on the ringer test. HQ Comments: Any load on the B+ line can cause 6 Blinks. Example: If the 200v line is loaded down will cause ...
Question about KP-53XBR300 53" Rear Projection Television
LOW B OCP/OVP (Overcurrent/over voltage). Possible causes: +5 line is overloaded. (A, B boards), +5 line is shorted. (A, B boards). Symptoms of the problem: No picture. replace the two mcz3001 ic's on
Question about FD Trinitron WEGA KV-32FS120 32" TV
...Low +B, OVP/ OCP Replace IC6501 & IC8002 [ MCZ3001D ] on D board. If you are handy with electronics stuff repair and can solder parts in circuit board then replace above said ICs or call local TV ...
...OCP Low B and +B line detect DET SHORT, and shut-down POWER ON RELAY. Reset by turning power on/off. In case of +B is loaded approx. 1.5A or more, microcomputer detects it via IC5005. OVP In case of ...
Question about FD Trinitron WEGA KV-30HS420 30" TV
LOW +B OCP/OVP (overcurrent/overvoltage)" and the probable cause locations listed are as follows: 1. +5 line is overloaded (A, B, M boards) 2. +5 line is shorted (A, B, M boards) 3. IC504 is faulty (A
...LOW B OCP/OVP (Overcurrent/over voltage). Possible causes: +5 line is overloaded. (A, B boards), +5 line is shorted. (A, B boards). Symptoms of the problem: No picture. It sounds like it will need ...
Usually answered in minutes!
2,410 Questions
2,254 Questions
1,646 Questions
1,423 Questions
1,438 Questions