High Limit Switch High limit switch went out on deep fryer. Cannot find anybody that has part. The actual switch didn't have a manufacture listed on it just these numbers: E50023LR30247 The thermostat
Question about Jewel Series Topaz Plus Hot Tub
...high limit sensor pulled out of the housing. The water temperature needs replacing not the high limit found usually in the filter well question is about the heater - is the tub up to temperature when ...
Question about 2 Person Spa Hot Tub 8 Hydrotherapy Jets 3/4 Hp Pump
...look it may take longer to heat to desire temp. if nothing chang have you adjust the temp higher . if everything check ok check high limit switch next to the control box ussualy red bottom push soft ...
...either have the temperature/high limit sensors tested or replaced. Also, try resetting the tub by cutting power to it for 5 minutes if you haven't already done so. most likely is the high limit ...
Question about Laars Lite 2 Pool Heater 250,000 Btu / Natural Gas
...used for the pool. Check your high limit switch inside of the heater. Usually when the high limit switch pops it will take about 4 to 6 hours for it to reset itself without you resetting the
OH display and still heating OH is overheat situation. high limits should shut down tub after 108 degrees.....high limits are shot.....replace the circ board
Question about Dream Maker Ez Spa Hot Tub
...high limit sensor? Or both? When I reset the hot tub I heard the high limit sensor clicking t My cal spa hot tub says OH and Sn... do I need to replace just the heat sensor or high limit sensor? Or ...
Question about Dream Maker Ez Spa Hot Tub
I would start by looking at the high limit switch. Look for a little reset button. A high limit switch trips when it senses high temperature, often from heater trying to run with Inadequate water flow
Question about Dream Maker Ez Spa Hot Tub
How do I fix high limit switch failure on Aruba 1060 hot tub Replace the switch. and check recirculation pump
Question about Dream Maker Ez Spa Hot Tub
high limit switch may be housed in a thermowell. If the water temperature in the thermowell is the same as the water temperature in the rest of the spa, the switch is damaged and needs to be replaced.