Questions & Answers for: indoor sensor

Question about Mr. Slim MXZ30TN Air Conditioner

1 Answer

...indoor coil temperature. On later type remote controllers you can get all operating data like temp sensor data but you will need a service manual to do this. Or you can measure the ohms resistance of ...

Ad

Question about Mr. Slim MXZ30TN Air Conditioner

1 Answer

...of indoor and input of outdoor. If no power you have to check indoor room temp sensor through which thermostat send command to outdoor unit. If your sensor is good, you have to repair/replace your ...

Ad

Question about Mr. Slim MXZ30TN Air Conditioner

1 Answer

...out sensor. Indoor Pipe Sensor or Outdoor Sensor Assy fault, Open or Short. Disconnect from PCB and measure resistance. Air sensor = 10 kOhm at 25C, Pipe sensor = 5 kOhm at 25C. If not replace

Question about Mr. Slim MXZ30TN Air Conditioner

1 Answer

...sensor Indoor unit return air sensor fault. Disconnect sensor from PCB and measure resistance. 8 kOhm at 30C and 13 kOhm at 20C if not replace sensor. Indoor Pipe Sensor or Outdoor Sensor Assy fault, ...

Question about AW1203B Air Conditioner

2 Answers

...indoor sensor and reset.Sometimes indoor pcb shows fault code due to sensor short. After replacing sensor it will show only A! or sometimes no error. If it shows A1, you have to repair/replace PCB. ...

Question about LS-L1210CL Mini Split Air Conditioner

2 Answers

...Indoor Pipe Sensor Disconnect from PCB and measure resistance. Pipe sensor = 5kOhm at 25C. If not replace pipe sensor. Thanks and hope helpful? sabro split ac 1 ton. problem is ac off after 17 ...

Question about 18000 Btu 20 Seer Ductless Mini Split Heat Pump

1 Answer

...indoor pipe sensor fault. You will need an air con tech or electrician to do this as the sensor is wired into the indoor board. Gree parts can be a bit difficult to obtain but a similar sized pipe ...

...Indoor temperature sensor open or closedcircuit. Display = Indoor. Indoor Operation = ON Error code = C2 or CH2 Flashing Light = 2 Fault = Outdoor temperature sensor open orclosed circuit. Display = ...

Question about 18000 Btu 20 Seer Ductless Mini Split Heat Pump

1 Answer

Indoor intake air temperature sensor abnormality Continue for 5 sec. - • Intake air temperature sensor (detec tive or disconnected) H15 Outdoor compressor temperature sensor abnormality Continue for 5

...sensor is outdoors, outdoor temp is displayed and when indoors the indoor temp is displayed. Is there some way to set it up to work properly or do I just leave the sensor indoors? The display has the ...

Not finding what you are looking for?

Ask a Question

Usually answered in minutes!

Top Heating & Cooling Experts

Paul Carew

Level 3 Expert

3808 Answers

john h

Level 3 Expert

29494 Answers

Brad Brown

Level 3 Expert

19187 Answers

Are you a Heating & Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...