...that it installed correctly or puched in all the way or it could be that the post corona wire or grid is broken or fell off.This would cause your dark
...sorry to say. What is the condition of drum and starter? What about the charge assembly? Is the grid still in good
...grid and reassemble. If the corona shell or the scoritron is discolored, clean them with a glass cleaner and soft cloth. Keep the drum covered with paper so it is not exposed to direct light for any ...
...horizontal lines appear across face of all copies This is usually caused by a dirty main charger grid, try cleaning it per the instructions in your operators guide. If you don't have the guide you ...
...this can be an issue with the following check the comb electrode this is also know as the charge grid is it dirty damaged clean this unit replace comb electrode if damaged is the cleaning blade ...
...grid and reassemble. If the corona shell or the scoritron is discolored, clean them with a glass cleaner and soft cloth. Keep the drum covered with paper so it is not exposed to direct light for any ...
...across them Clean or change the OPC drum cleaning blade,the drum.Clean the charge corona wire and grid,clean the optics,mirrors,transfer and separator corona
Question about EP4000/5000 CS/PRO Copier
...the erase lamp obturation filter(located in OPC drum area,clean the drum charge corona
...the old drum unit,remove the drum and the drum cleaning blade,clean the charge corona wire and grid,install the new drum and drum cleaning blade,clean the image transfer /separator corona ...
...when printing or copying the whole paper comes out black Check the image unit. And check the charge grid on the top of the drum. also check the three little springs that the top of the machine comes ...