Questions & Answers for: goodman furnace stay lit

...Goodman GMPN 120-5 I am not familliar with that proticular model but continous flash could be reversed polarity. That is where I would start. Furnace will start then sec later it will turn off. Then ...

Ad

Question about GMS90703BXA Heater

1 Answer

Goodman Furnace, to let you know that it is Valt ( or Fault) #1 that is not staying lit. If you could help or give any suggestions, it would be appreciated. Thanks so much!A.A AA, it could be a lot of

Ad

Question about GMS90703BXA Heater

1 Answer

furnace will not stay lit The problem is not constant. Sometimes it works, and sometimes not. Sounds like a thermocouple, or flame sensor. Are you skilled on working on appliances of this sort? I am a

Question about GMS90703BXA Heater

1 Answer

...lit Furnace starts up then shuts down. Flame starts and then goes out.. The air compressor works fine. if the main burners are firing but goright out it could be the flame sensor which is a straight ...

Question about GMS90703BXA Heater

2 Answers

...lit for a few seconds then only cold air blows through the house Your furnace needs a tune-up. MODERN FURNACES REQUIRE REGULAR MAINTENANCE! try cleaning your flame sensor with sand paper its an "L" ...

goodman gmpn 100-4 REVB furnace that will not stay lit I have a goodman gmpn 100-4 REVB furnace that will not turn on, valve opens ignitor lights but it does not stay lit, tries a few times then shuts

Question about GMS90703BXA Heater

2 Answers

...adjust if flame is good and the therm/coupl is not covered in soot(wipe clean if has build up)thermocouple gone bad replace what type of furnace as listed there is no pilot on this Goodman ...

Goodman GMPN060-3 Furnace will not stay lit.has new Flame Sensor & Control Board.All Switches check Good? Help!! possible faulty gas valve if all fail safes stay closed. make sure flue is clear ...

Goodman GMP Furnace problem. Original problem is Goodman GMP Furnace problem. Original problem is that the Power Vent motor would not shut off after reaching tempurature. I found on the Board the ...

goodman furnace. The problem I have is when the ignitor comes on then the blowers turn on however they only stay lit for a few minutes, then it turns off and repeats this process. Clean or replace the

Not finding what you are looking for?

Ask a Question

Usually answered in minutes!

Top Heating & Cooling Experts

Paul Carew

Level 3 Expert

3808 Answers

john h

Level 3 Expert

29494 Answers

Brad Brown

Level 3 Expert

19187 Answers

Are you a Heating & Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...