...reset it? Did it come right back? Is the fuser warm to the touch? If so it is most likly to be one or both of the termister in the fuser. If it is cold it may be the fuser heatting lamp or thermal ...
...fuser lamp has a malfunction Fusing unit SCs displayed on the operation panel. The machine is disabled. The user cannot reset the SC. Turn the main power switch off then on before entering SP mode. ...
...fuser units to work in the Aust Model? A new thermister? new lamp? cost? etc. Only the lamps, p/n AX430070 (pressure) AX430159 (heat roll) the watts of the lamps are the same, just different voltage, ...
ricoh ft5832 code e5 47 E547 is a level A code (need to do a fuser SP reset, copier is inop) the fuser lamp continuosly stays on. Probably a shorted triac or fuser board problem.
...lamp in fuser. (lamp is good if you get continuity) (lamp is bad if open) 2) Check the thermostat. (thermal control device) (triggers if unit gets too hot) 3) Also check thermistor (monitors temp of ...
...= The melting temperature measured by thermistor is less than 71 C The problem lies in the fuser: - Thermistor fuser defective or incorrectly installed - Fuser Lamp failure Solution: Replace ...
...fuser lamp & thermal fuse > have you cleaned or replaced the two thermistor's???? If one of them are shorting out, the fuser will never warm up... Have you cheated the front door and look ...
...fuser connection *Heat lamp consecutive on error - Check HR thermistors with SP1-106 001 (ctr) and 002 (ends) *Heat lamp consecutive on error - Heat roller lamp defective *Heat lamp consecutive on ...
...fuser lamp and or the thermistor, or the thermal fuse. If you can put you hand near, and I did say near, because the fuser is very hot and can burn you, you should feel heat. Use an inferred ...
Question about Aficio Sp C320dn Laser Printer - Color - 1200 X 1200 Dpi Print -
...lamp. Resetting the code: Execute "Fuser SC Reset" with Some (printer models) or "Engine Maintenance Menu" (MF model) to recover the machine after completing the recovery procedure. Otherwise, the ...
Usually answered in minutes!
629 Questions
382 Questions
267 Questions
215 Questions
218 Questions