fedders room air conditioner we unplugged the unit and now it will not power on. We tried to remove the front (removed the 2 screws first) and cannot get it off. WE are looking for the reset button as
Question about X Chassis A6X08F2A Air Conditioner
red wire from NC on blower delay relay to stop it. blower relay Bd is new Most of the time on Fedders unit one speed for heat comes off sequencer. This a low speed for heat. You may have bad sequencer
Question about A6P09D2B Portable Dual Hose Room Air Conditioner
stopped running and red light and beep it wont turn back on and I have reset everything. I do not know what the flashing red light means with the ! have you checked the condensor coil on it where is ...
Question about Electronic Programmable Heat/Cool Thermostat - CT3300A100 Heater
...Fedders model cnx 110 t3b. we are trying to change to new thermostat. Can you tell us what these wires go to... W1, X, Y2, Y1, G, Rc and Rh. They don't even have these on the new one, just a couple ...
Question about Electronic Programmable Heat/Cool Thermostat - CT3300A100 Heater
...fedders f80a heater and dont know how to wire thermostat If you have a gas heater, you will have a stat with these markings. RC, RH, Y, G, and W. Your Red wire will connect to either of the R ...
Question about Electronic Programmable Heat/Cool Thermostat - CT3300A100 Heater
...fedders A24C1X air handler and i am replacing the transformer. i was instructed to buy a universal one which i did. i belive i figured out the wiring. my new ones common is white and the orange wire ...
...Fedders model sfpeb08f2b is on. I have cleaned the filter in the back, is there another filter that I am missing? The light will not go off... I had the same problem, remove the filter and wash with ...
my unit is 220v single phase ----the wiring in the wall is one black, red, white and a ground wire ----what is the proper connection to the outlet The black is a 110 "leg" the red is a 110 "leg" the ...
Question about A3X05F2A Air Conditioner
What fan and compressor colors go together?, blk,red,yel,org, and white. Where on capacitor do they connect? One color to another. Does yellow =Brown? that sounds like fan speed selectors
Question about A3X05F2A Air Conditioner
Fedders air conditioner but cannot tell if it is 110 or 220. the numbers are 146y and SN #141448 Well 110 v will have black, hot, white, neutral and green for ground. 220v usually will have black, hot