F2 00 Toner control sensor open 22 LCC 24v power abnormality 02 Toner motor connector unconnected 50 Non supported option connection (Desk Unit) 31 Process control trouble (Drum surface reflection) 51
...F2-37 & 2) is U2-00. The U2-00 I can clear everytime. The F2-37 won't clear for hours. The only things is to leave it unplugged for several hours then try again. Sometimes it takes several ...
...to a Transfer problem? "F2-31"Image density sensor fault "F2-32"Drum mark sensor fault "F2-33"Grid voltage correction problem "F2-35"Grid voltage correction problem "F2-37"Drum mark sensor ...
f2-37 Your drum mark is dirty or scratched or drum sensor, if not , change a new drum. Hello sir; I'm not sure this code can be reset or not bt you try; press "program", 'interupt", "clear", 'interupt
What is Code: F2-37 http://www.copytechnet.com/forums/sharp/15117-sharp-ar407-code-f2.html
F2 with sub code 37 - drum mark sensor adjustment required.You may post further comments for more help or information...... Good Luck!! Thanks for using FixYa!! how to clear the F2 error code please i
...F2-37, Drum mark or image density. You can execute 44-6. This should show which is out of range. Pull the drum unit out & clean both sensors. Check that the blade is cleaning from end to end that ...
F2-37. how do i resolve it? You have to change the developer and to purchase a new branded toner then you have to change it and some more steps are there feel free to rate this articile I can give you
...F2-37" Drum mark sensor fault Cause : CRUM chip defect OR Improper developing unit Check and remedy : As you have already replaced the tonner, we can suggest Replace the CRUM chip,Replace the ...
...sub code 33 - grid voltage wrong, either too high or too low; F2 with sub code 35 - grid voltage correction will not work during simulation; F2 with sub code 37 - drum mark sensor adjustment