Questions & Answers for: deep fryer pilot blows

Question about SG18S Deep Fryer

3 Answers

Fryer Problem is pilot outage. Already have replaced high limit switch, Thermopile, and pilot assembly. Pilot seems to be going out when t-stat is satisfied and burners are shutting off, seems to be a

Ad

Question about 2424G Deep Fryer

2 Answers

...and orfices in the fryer are clogged.propane burnes very dirty. Poor ignition at burner @ pilot... check pilot strength and position... If this fryer is fan assisted...then fan might not be

Ad

pilot blows out as soon as tempiture is reached try removing all electrical connections and polish all contact points (emery cloth) including screws. Also try tapping on the regulator, magnets may be ...

Question about IFS40 Deep Fryer

1 Answer

...pilot light. So the most posible reason is to replace the thermocouple which is the cheapest part. Their is a very small chance that the gas valve is faulty but this depents how old the fryer is and ...

Question about SG14 Deep Fryer

1 Answer

...pilot light lights and as soon as i let go it blows out and my fryer is not a few years old Two things to check. Make sure you have continuity through the terminals on the high limit. Also make sure ...

Question about ERD85 Deep Fryer

1 Answer

...pilot keeps blowing off. ther e are 2 pilots and one has the problem. pl help Hi, The thermocouple that senses the flame is bad... on most deep fryers they are actually "power pile generators" they ...

...deep fryer chemney needs to be check out. 2. the unit door blows open caused by what we call this delay lighting, it is quite dangerous, you should check out the whole unit , the pilot light may be ...

Question about IFS40 Deep Fryer

1 Answer

two imperial isf40 fryers taken apart and cleaned, inside did get wet. Now trying to light them both and neither will light and no gas getting to pilot light but gas is for sure working up to the unit

BLOWS OUT PILOT LIGHT CAN WORK FOR 3 OR 4 TIMES SHUTS DOWN NICELY THEN WOOF SMALL BLOW BACK CAUSEING PILOT TO BLOW OUT THEN HAVE TO WAIT 10MINS TO RELIGHT ALL BURNERS ARE CLEAN AND NEW THERMO COUPLING

...There is no flame sensor on a fryer. The high limit is responsible for a pilot going out. If the millivolts are dropping during use, the pilot may also go out. It is a simple fix, just need more

Not finding what you are looking for?

Ask a Question

Usually answered in minutes!

Top Kitchen Appliances - Others Experts

Cindy Wells

Level 3 Expert

6688 Answers

Brad Brown

Level 3 Expert

19187 Answers

john h

Level 3 Expert

29494 Answers

Are you a Kitchen Appliances - Others Expert? Answer questions, earn points and help others