Questions & Answers for: crank code kohler generator

Question about 12 kW Emergency Power System - 12RES-L

1 Answer

...code residential generator Engine cranks, turns over briefly then shuts off and UU code appears. Checked oil: OK Suggestions? Could be the battery voltage. If your battery is not charging properly, ...

Ad

Question about 12 kW Emergency Power System - 12RES-L

1 Answer

...kohler 12 res generator the code oc comes up. It will not turn over at all. I checked the battery and made sure it was putting out 12 volts. Checked the starter for any loose wires and did not find ...

Ad

Question about 12 kW Emergency Power System - 12RES-L

3 Answers

...code, today also got the uu signal. any ideas to make this auto start work. 100% start on manual mode. thanks U need to make sure that the relay driving ur auto start stay closed all thru the crank ...

Question about 12 kW Emergency Power System - 12RES-L

1 Answer

...CRANK ERROR CODE. IT REMINDS ME OF WHEN YOU CRANK A CAR WITH LOW BATTERYAND THE VOLTAGES DROPS BECAUSE IT CAN'T HANDLE THE AMP LOAD If the succession is 3-5 sec crank - 3-10 sec pause, it is OK, but ...

Question about 12 kW Emergency Power System - 12RES-L

1 Answer

...Kohler Propane Generator ran for 8.5 hours and shut down for overspeed. later it started up again and shut down for under frequency. Now it won't even turn over. Where do I start. I checked the ...

Question about 12 kW Emergency Power System - 12RES-L

1 Answer

Had a bad battery and changed it out. Now Im still getting the overcrank code and it will not turn over. How do I reboot it? Check for a burned fuse or tripped breaker to the cranking circuit.

Question about 12 kW Emergency Power System - 12RES-L

1 Answer

Kohler 12res installed 06/06, replaced controller in Dec 10, has worked fine since . This past weekend with storm, generator started and has run for 3 days , generator shut down with SCFO code - which

Code TOA-1752-NBB When I went to winterize my generator last year I ran it to warm up the engine and run the fuel stableizer through and it started and ran fine for about 10 minutes. when I stopped it

Question about 12 kW Emergency Power System - 12RES-L

1 Answer

...code. If I reset auto switch by clicking off, then clicking run, then clicking auto it will start. Any thoughts on this issue? OC is Over Crank which generally means it cranked and cranked and failed ...

...code warning. I clear it and then try to restart and it comes up again. The battery appears to be good. Locked Rotor is reported as an overcrank fault "OC". You first need to verify the engine fails ...

Not finding what you are looking for?

Ask a Question

Usually answered in minutes!

Top Electrical Supplies Experts

Brad Brown

Level 3 Expert

19187 Answers

john h

Level 3 Expert

29494 Answers

ADMIN Andrew
ADMIN Andrew

Level 3 Expert

66963 Answers

Are you an Electrical Supplies Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...