Questions & Answers for: atdc sensor setting minolta

Question about Di152 Laser Printer

2 Answers

ATDC sensor is reading toner supply incorrectly, now this Toner Density Control sensor sits inside the developer unit of this machine, and toner is feed into it, where the atdc sensor reads the amount

Ad

Question about EP4000/5000 CS/PRO Copier

1 Answer

...ATDC set which was initially at 140 against 6.0 can now be adjusted lower than 140 but the current still remained 0%. i was forced to run F5 and it shut down with a C00f31 code. and the dark ...

Ad

Question about bizhub 250 All-In-One Laser Printer

6 Answers

...ATDC sensor failture, first check the level history in service mode,press utility/counter, stop-0-0-stop-0-1, press the password, "00000000"and the press level history, normally, atdc sensor have ...

Question about bizhub 250 All-In-One Laser Printer

2 Answers

...atdc sensor gainset the value to about 165then back all the way out to the ready screen and power the machine off then back on and replenish toner in the user management screen. Obviously the dv unit ...

Question about Bizhub-200 Minolta Printer

1 Answer

...stop,0,0stop,0,1 4 select tech rep choice mode 5 select printer tab 6 select atdc sensor gain 7 set value to 167 back all the way out to the ready screen then power the machine off then on. should ...

Question about bizhub 250 All-In-One Laser Printer

2 Answers

...atdc sensor gain 7.set value to 165 back out to the ready screen then power off then on the machine have done this many times and just fixed one today with the same problem Is this the same way to ...

Question about DiALTA Di200 Copier

1 Answer

...ATDC Sensor E1 The value of data read by E1 is faulty. [E1 reading is 7% or less (3.92V or more) or 19% or more (1.41V or less).] Are PJ40, CN50, CN17, and PWBA PJ15A connected properly? (NO) Connect ...

Question about DiALTA Di200 Copier

1 Answer

...ATDC Sensor E1 The value of data read by E1 is faulty. [E1 reading is 7% or less (3.92V or more) or 19% or more (1.41V or less).] C0F32, C0F33 Are PJ40, CN50, CN17, and PWBA PJ15A connected properly? ...

Question about DiALTA Di200 Copier

1 Answer

Have Minolta Bizhub C353 keeps giving me C-2555 message. Is there a way to fix this check imaging unit problem, it is counter full or ATDC sensor problem. try to calibrate color first & setting.

Question about bizhub C250 All-In-One Laser Printer

1 Answer

error c2557 you need to set the ATDC sensor gain from the tech rep mode. Remove the toner before you run the F8 function.

Not finding what you are looking for?

Ask a Question

Usually answered in minutes!

Top Office Equipment & Supplies Experts

k24674

Level 3 Expert

8093 Answers

Brad Brown

Level 3 Expert

19187 Answers

ADMIN Andrew
ADMIN Andrew

Level 3 Expert

66832 Answers

Are you an Office Equipment & Supplies Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...