water coming out of unit. Your drain pipe is blocked. You can **** on the outlet pipe on the outside of the building to clear it. Unless you have a water vacuum machine which you could also use
Question about LS-K2430HL Heat Cool Mini Split Air Conditioner
no more condense water outside, leaking heavy inside the room from the bottom of the handler Take a shop vac and **** the pipe out from the outside. You have a blockage in the condensate pipe.
Question about Art Cool LA121HNP Split System Air Conditioner
...drain line which drains humid water the a/c coil collects. To clean you can try compressed air,blow through the pipe.Or take pipe apart and flush it out. Have the unit off when doing ...
Question about Art Cool LA121CNP wall/window Air Conditioner
if both copper pipes are insulated combinedly what will happen (any problem in the compressor) Both pipes haveto be insulated by a good insulators.{PUF}good insulation covering on the pipes so as to ...
the indoor split system is dripping water what can i do? There should be a drain pipe to send the condensed moisture outside. Take the cover off the unit and check where the tray is and unblock the ...
Question about LS-L1210CL Mini Split Air Conditioner
my air contidioner has ch46 flashing and it does not start, can you please let me know what is the problem . Suction pipe sensor missing or faulty.. suction pipe is your larger pipe . sensors like ...
Question about LS-L1210CL Mini Split Air Conditioner
...Sensor or Outdoor Sensor Assy fault, Open or Short. Disconnect from PCB and measure resistance. Air sensor = 10 kOhm at 25C, Pipe sensor = 5 kOhm at 25C. If not replace
...Keep cool mode and temp setting minimum 3 degree less than room temp. Check indoor unit return air sensor. Disconnect sensor from PCB and measure resistance. 8 kOhm at 30C and 13 kOhm at 20C if ...
...not stop It could be that your waste pipe is pushed to far down into the drain not giving you an air break between the waste pipe and the water in the bottom of the drain pipe causing the water to ...
...Sensor or Outdoor Sensor Assy fault, Open or Short. Disconnect from PCB and measure resistance. Air sensor = 10 kOhm at 25C, Pipe sensor = 5 kOhm at 25C. If not replace