older Amana quiet zone Model P12QZ22RC will not turn off when dial is in "off" position. replace dial switch.
Question about Quiet Zone 12M12TA Air Conditioner
Problems with Amana Quiet Zone 12M12TA, kicks off after short runtime, but other times runs for an hour cooling OK. Hear a clicking when it shuts down? Could not find a fuse ot relay? Does it run ...
Amana Quiet Zone air conditioner 12m12ta the operation indicator and timer indicator are flashing constantly... I tried unplugging and then plugging it back in no change. Your help would be very much ...
Noisy Amana Quiet Zone air conditioner My air conditioner works (well, it blows out cool air...), but it is really loud and the case gets hot. This problem just cropped up a few days ago. It is loud ...
runs but doesn't cool I would suspect the compressor is not coming on. Look at the capacitor they are dual type and one side could be out. Also how old is the unit check the thermostat quick way would
Question about Quiet Zone 12M12TA Air Conditioner
Where do i find the model # on my a/c unit. It is 14 years old. The model number should be inside the area on the front that the cold air comes out. If not it will be located on the front bottom edge.
Question about Quiet Zone 12M12TA Air Conditioner
Need to re-install through a rebuilt wall. Where can I locate a sleeve? Middle of the room and also above 4 feet height from floor.
i can not find how many btus it is 11800 BTU, hope this helped Tim 11800 BTU
not cool enough What is the temp of the air copming out of it at this time depending on the room temp it shuld be about 15-20 degrees cooler than room temp
Question about Quiet Zone 12M12TA Air Conditioner
Fan continues to run in the off position? The contacts in the switch are welded shut (if this is a portable unit). On a central system, the fan relay contacts are welded shut.