Questions & Answers for: 120v timer

Ad

Question about GE 56941 24-Hour Outdoor Timer Switch

1 Answer

...timer 120v how to wire this ge timer in 120v were should i put my H N,i have the GE150787. Open following links for GE timers and 15087 ...

Ad

Question about 4001-00 24-hr Timer Control 120v Ac Cd101

1 Answer

...Timer operates when clutch is de-energized. Simple replacement for 120V 2-NO 2-NC is GE15207: Selectable voltage http://waterheatertimer.org/GE-timers-and-manuals.html#15207 Tork TU series also ...

Ad

Question about 651A Photocell Controlled Mechanical Outdoor Timer with One Grounded O

1 Answer

...120V timer. 120V Black Hot wire from circuit breaker connects to Pole L There is a brass bridge that connects Pole L and Pole 1 >> if this is missing, put a jumper wire that connects both Poles ...

Question about 4001-00 24-hr Timer Control 120v Ac Cd101

1 Answer

...120V timer: -120V black wire from breaker goes to terminal2 -120V white wire from breaker to terminal1 -jumper wire from terminal2 to terminal3 -Load black wire to terminal4 -Load white wire to ...

Question about C8865 Timer, 1HR CYCLE TIME, 30 SEC TRIP

1 Answer

120V timer. Timer has NO and NC terminals. NO terminal turns ON when timer turns ON NC terminals is ON all the time, except when timer turns ON. At this point NC terminal turns OFF. You have 3 things:

Question about & Indoor/Outdoor Rain Tight Timer

1 Answer

...120V timer Clock motor can be replace with identical 120V clock motor from Grainger http://www.grainger.com/Grainger/INTERMATIC-Time-Clock-Motor-1PNK1?Pid=search Timer mechanism snaps out and clock ...

Question about T104 24h 208-277v Mechanical Time Switch

1 Answer

...timer T104 240 v to a 120v? T104 is 240volt timer. Timer has terminals A 1 2 3 4 T-104 clock motor must receive 240Volts to operate. Clock motor wires are white-colored and can be seen connected to ...

Question about Dayton Solid State Timer On Delay Time Relay

1 Answer

...120V timer can be used to control 240V load. Also the 120V Dayton can operate 120V double-pole contactor, and then the contactor controls 240V Load. ...

Question about 4001-00 24-hr Timer Control 120v Ac Cd101

1 Answer

...120v at timer and at outdoor fixture but light will not turn on nor will the outside outlets also on this circuit, and they read 105v. Is this an old timer? Maybe there is corrosion on the contacts ...

Question about 4001-00 24-hr Timer Control 120v Ac Cd101

1 Answer

Timer (120V) Wiring Guidance This timer (T103P) looks identical to the 240V timers I have hooked up. The box says "120V" but the instructions/diagram show 120/208/240. I am putting the timer

Not finding what you are looking for?

Ask a Question

Usually answered in minutes!

Top Electrical Supplies Experts

Gene Haynes

Level 3 Expert

5391 Answers

Marvin
Marvin

Level 3 Expert

85239 Answers

Brad Brown

Level 3 Expert

18513 Answers

Are you an Electrical Supplies Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides