Inside the unit on the left side of the evaporator coil there should be a channel that allows the water to drain to the outside of the unit and cool the condenser coil use compressed air to clean this channel (a.k.a. keyboard cleaner) were safty glasses and make sure unit is unplugged then check drain to make sure it is clear before running the unit.