Question about Precor EFX 546i Elliptical Version 4

1 Answer

What does error code 30 mean on the Precor efx 576i?

Posted by clytle504 on

Ad

1 Answer

Sportsmith LLC

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    Superstar:

    An expert that got 20 achievements.

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

  • Precor Master
  • 918 Answers

Precor Error 30, 31, 32 and 33, Communications Error Probable Cause 1. Bad interconnect cable between upper PCA and lower PCA.
2. Interconnect cable is mistakenly plugged into the CSAFE connector at the upper PCA.
3. Elliptical 5.17 equipped with old software version 1.01 in upper and lower PCA.
4. Upper and lower PCAs have mismatched software.
5. Another component plugged onto the PCA is overloading the +5VDC power supply.
6. Bad lower PCA.
7. Bad upper PCA.
Corrective Action

  1. Test unit with a know good interconnect cable or test the interconnect cable for continuity. Replace interconnect cable if necessary.
  2. Disconnect the interconnect cable from the CSAFE connector and attach to the proper position on the upper PCA.3.
  3. Replace the upper and lower software of the 5.17 elliptical with the most current versions.4.
  4. If one of the PCAs is found to have software version 1.01, replace it with the most current software version.
  5. Disconnect all components from the upper and lower PCA leaving the data cable connecting between the upper and lower PCAs and the AC power going to the lower PCA. If the unit shows any error other than the error 3x, reconnect components one at a time. Reset power between each newly connected component until the error 3x reappears. Whichever component was last connected when the error 3x reappears, is the cause for the error. Replace the faulty component.
  6. Test unit with a known good lower PCA. Replace the lower PCA if necessary.
  7. Test unit with a known good upper PCA. Replace the upper PCA if necessary.

Precor Error Code 30 31 32 33

Posted on May 15, 2014

Ad

4 Related Answers

Anonymous

  • 13 Answers

SOURCE: i pulled the plug on my precor efx and now it wont

yes, we can help. 281-469-8506 www.nashsfitness.com

Posted on Aug 10, 2009

Ad

Anonymous

  • 1 Answer

SOURCE: looking for repair manuals and error codes for

Could you please advice about ERROR 29 fo C956i/C966i treadmill.

Posted on Mar 04, 2010

maxtreadmill

John Mazmanian

  • 832 Answers

SOURCE: belt replacement for precor efx 645 verison 1

You may have to purchase the belt from a Precor dealer in you area, if you don't have one then call Precor directly @ 1-800-347-4404 and they will help you. Most of these part have not hit the secondary market yet and Precor pretty much call the shots.

Posted on Mar 13, 2010

ZJLimited

ZJ Limited

  • 17970 Answers

SOURCE: How do I replace the

Check this reference guide in video: Precor+elliptical+trainer+change+belt

Hope helps.

Posted on Dec 28, 2010

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

My precor 576i cross ramp will not move


Is the battery low?

Btw, I’m available to help over the phone in case u need at https://www.6ya.com/expert/russell_1d1c35fa8a5a0be4

Aug 20, 2014 | Precor Efx 576i Experience Elliptical...

1 Answer

Precor efx 576i resets everytime user changes direction


Does the lift work? If not, the battery is dead. Replace it.

Btw, I’m available to help over the phone in case u need at https://www.6ya.com/expert/russell_1d1c35fa8a5a0be4

Feb 17, 2014 | Precor Efx 576i Experience Elliptical...

1 Answer

576i resistance not increasing precor


If the display stays at 1, then the UP button may be at fault, in which case you would need a new keypad.

Btw, I’m available to help over the phone in case u need at https://www.6ya.com/expert/russell_1d1c35fa8a5a0be4

Jan 02, 2014 | Precor EFX 546i Elliptical Version 4

1 Answer

How to fix Precor EFX 5.17 error code 30


Precor Error 30, 31, 32 and 33, Communications Error Probable Cause 1. Bad interconnect cable between upper PCA and lower PCA.
2. Interconnect cable is mistakenly plugged into the CSAFE connector at the upper PCA.
3. Elliptical 5.17 equipped with old software version 1.01 in upper and lower PCA.
4. Upper and lower PCAs have mismatched software.
5. Another component plugged onto the PCA is overloading the +5VDC power supply.
6. Bad lower PCA.
7. Bad upper PCA.
Corrective Action
  1. Test unit with a know good interconnect cable or test the interconnect cable for continuity. Replace interconnect cable if necessary.
  2. Disconnect the interconnect cable from the CSAFE connector and attach to the proper position on the upper PCA.3.
  3. Replace the upper and lower software of the 5.17 elliptical with the most current versions.4.
  4. If one of the PCAs is found to have software version 1.01, replace it with the most current software version.
  5. Disconnect all components from the upper and lower PCA leaving the data cable connecting between the upper and lower PCAs and the AC power going to the lower PCA. If the unit shows any error other than the error 3x, reconnect components one at a time. Reset power between each newly connected component until the error 3x reappears. Whichever component was last connected when the error 3x reappears, is the cause for the error. Replace the faulty component.
  6. Test unit with a known good lower PCA. Replace the lower PCA if necessary.
  7. Test unit with a known good upper PCA. Replace the upper PCA if necessary.

Precor Error Code 30 31 32 33

Nov 01, 2011 | Precor EFX 546i Elliptical Version 4

1 Answer

I have a Precor EFX 5.17 and received an Error Code 30 while I was using it. What is an Er30 and why did I receive this?


Precor Error 30, 31, 32 and 33, Communications Error Probable Cause 1. Bad interconnect cable between upper PCA and lower PCA.
2. Interconnect cable is mistakenly plugged into the CSAFE connector at the upper PCA.
3. Elliptical 5.17 equipped with old software version 1.01 in upper and lower PCA.
4. Upper and lower PCAs have mismatched software.
5. Another component plugged onto the PCA is overloading the +5VDC power supply.
6. Bad lower PCA.
7. Bad upper PCA.
Corrective Action
  1. Test unit with a know good interconnect cable or test the interconnect cable for continuity. Replace interconnect cable if necessary.
  2. Disconnect the interconnect cable from the CSAFE connector and attach to the proper position on the upper PCA.3.
  3. Replace the upper and lower software of the 5.17 elliptical with the most current versions.4.
  4. If one of the PCAs is found to have software version 1.01, replace it with the most current software version.
  5. Disconnect all components from the upper and lower PCA leaving the data cable connecting between the upper and lower PCAs and the AC power going to the lower PCA. If the unit shows any error other than the error 3x, reconnect components one at a time. Reset power between each newly connected component until the error 3x reappears. Whichever component was last connected when the error 3x reappears, is the cause for the error. Replace the faulty component.
  6. Test unit with a known good lower PCA. Replace the lower PCA if necessary.
  7. Test unit with a known good upper PCA. Replace the upper PCA if necessary.

Precor Error Code 30 31 32 33

Feb 22, 2011 | Precor EFX 546i Elliptical Version 4

1 Answer

Knocking/bumping sound while pedaling Precor 576i elliptical. It is coming primarily from the right side/pedal on the downward strike. What could be causing this?


It could be the input drive bearings going out. I would suggest removing the back side covers of the unit and inspecting the drive assembly when its in use. Watch for deviations in the the circular motion of the crank arms. If it moves side to side or drops in the rotation its time to have the input replaced.

Feb 05, 2011 | Precor EFX 546i Elliptical Version 4

1 Answer

Getting stuck key msg for my EFX 576i. I've unplugged the keyboard and plugged it back in but no help


Precor Error 05, Key Depressed at Power Up Probable Cause 1. A key is permanently depressed on the display.
2. An interface chip (IC) has failed in the upper PCA's keypad.
3. Liquid (cleaning solution or sweat) may be on the surface of a touch sensitive display.
Corrective Action
  1. Disconnect the keypad cable from the upper PCA. Reset power to the machine. If the Error 05 is eliminated, the keypad is the cause and should be replaced.
  2. Disconnect the keypad cable from the upper PCA. Reset power to the machine. If the Error 05 still appears, the upper PCA* is the cause and should be replaced. *Upper PCA's most commonly do not come with software. Remove the software (chip) from the existing upper PCA prior to replacement and install into the new upper PCA.
  3. Wipe away all liquid from the touch sensitive display. Reset power to the unit. If the Error 05 is eliminated, the liquid was the cause.

Precor Error Code 05

Jan 12, 2011 | Precor EFX 546i Elliptical Version 4

1 Answer

Error 45 on Precor EFX 546 Elliptical


Precor Error 45, Lift Moving in Wrong Direction Probable Cause 1. Lift motor hysteresis.
2. Lower PCA is bad.
Corrective Action 1. The error would usually occur when the lift was already in motion (usually downward) when a lift command in the opposite direction (upward) was made. Some lift motors used in production exhibited a very long turnaround time and the lift motor would still be moving in the original commanded direction while the control system was trying to move the lift in the opposite commanded direction. If the error continues to re-occur, replace the lift motor.
2. It is a rare condition, however if the lift moves in the opposite direction commanded, replace the lower PCA.

Precor Error Code 45

Jul 19, 2009 | Precor EFX 546i Elliptical Version 4

Not finding what you are looking for?
Precor EFX 546i Elliptical Version 4 Logo

585 people viewed this question

Ask a Question

Usually answered in minutes!

Top Precor Exercise & Fitness Experts

NOEL
NOEL

Level 3 Expert

8549 Answers

Ngoro

Level 3 Expert

2822 Answers

Andrew Taylor
Andrew Taylor

Level 3 Expert

34893 Answers

Are you a Precor Exercise and Fitnes Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...