Weiser Lock Powerbolt 1000 Lock Logo
Posted on Jun 23, 2011
Answered by a Fixya Expert

Trustworthy Expert Solutions

At Fixya.com, our trusted experts are meticulously vetted and possess extensive experience in their respective fields. Backed by a community of knowledgeable professionals, our platform ensures that the solutions provided are thoroughly researched and validated.

View Our Top Experts

After replacing the batteries on the Weiser powerbolt, the unit will work fine for several locks and unlocks. The lock will start beeping, and then the keyboard will go dead.I have tried changing batteries again and reprogramming, but I end up with the same result.

1 Answer

Anonymous

Level 3:

An expert who has achieved level 3 by getting 1000 points

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Vice President:

An expert whose answer got voted for 100 times.

  • Master 963 Answers
  • Posted on Jun 24, 2011
Anonymous
Master
Level 3:

An expert who has achieved level 3 by getting 1000 points

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Vice President:

An expert whose answer got voted for 100 times.

Joined: Mar 05, 2011
Answers
963
Questions
0
Helped
489408
Points
1500

This is the relevant excerpt from the Powerbolt programming and troubleshooting instructions:


Why is my Powerbolt 1000 unit beeping?
To determine why your lock is beeping abnormally, please follow these steps:

  1. Take out batteries and unplug powerstrip.
  2. Let it sit for 1 minute, then put the batteries back in and wait another minute.
  3. If it does not beep, the keypad needs to be replaced (17733-1).
  4. If the unit continues to beep, the powerboard needs to be replaced (A17734-3,3 Powerboard 1470 brass finish; A17734-3,26D Powerboard 1470 satin chrome finish; A17734-3,5 Powerboard 1470 antique brass finish).
The complete page that I cut this from can be found by cutting and pasting this link into your browser search bar:

http://www.weiserlock.com/Support/Faq/50160000000HhhZAAS.aspx

Since you've already gone through the battery change, this suggests that you need to replace the appropriate Powerboard for your lock.
So this is the link to Weiser Customer Support Page:

http://www.weiserlock.com/en/CustomerService/ProductSupport/SupportContact.aspx

I suggest calling the appropriate toll-free number and having a conversation with a representative about this problem, first of all to confirm that you need the part before you go through the expense. Secondly, your lock may be new enough for you to talk them into warrantying it, and thirdly, they will be able to get the correct part on order for you.

I hoe this has been helpful. Good luck!

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer

Need a video how to program my keyless entry deadbolt lock

Which manufacturer made the keyless deadbolt lock? Make sure that the batteries are good in the unit.

I have an older Weiser Powerbolt deadbolt lock that is programmed by taking off the cover on the inside of the door. This model has handheld remotes and the keypad. Inside there are three yellow buttons. Two match the cover's lock and unlock buttons. Press and hold the third button (in the center of the set of buttons). Then enter program in the code within a few seconds and press the enter button to set the code. If the unit beeps again, the code is set. If the unit doesn't beep, retry from the press and hold the Program button step.

Another model of the Weiser Powerbolt lock has the Program button either on the top left or lower right hand side of the board (depending on the way the door opens) under the cover. Press the Program button once and then enter the 4-8 digit code. Press the Lock button to set the code. If you hear a long beep, the code was accepted; otherwise try to program your code again.

Kwikset Powerbolt locks are programmed the same way as the second Weiser Powerbolt described above.

Kwikset SmartCode locks have their Program button in the center of the bottom of the control board. Otherwise the programming is the same as that given above for the second version of Weiser Powerbolt locks.

MiLocks have three buttons in a horizontal line. The left-most button is the Set button. Press this then enter the code followed by the Unlock button. The code must be entered within 5 seconds of pressing set.

Baldwin Hardware's Boulder series of keyless entry deadbolts are programmed just like the Kwikset SmartCode units.

I don't know of any videos. Most manufacturers do have PDF files with the programming instructions.

I hope this helps. Please add more information about your deadbolt for extra assistance.

Cindy Wells
(I end up replacing the batteries often on the lock I have; it seems like they last 6 months or less.)
1helpful
1answer

My Weiser powerbolt lock is beeping-changed batteries-won't stop

Why is my Powerbolt 1000 unit beeping?
To determine why your lock is beeping abnormally, please follow these steps:
  1. Take out batteries and unplug powerstrip.
  2. Let it sit for 1 minute, then put the batteries back in and wait another minute.
  3. If it does not beep, the keypad needs to be replaced (17733-1).
  4. If the unit continues to beep, the powerboard needs to be replaced (A17734-3,3 Powerboard 1470 brass finish; A17734-3,26D Powerboard 1470 satin chrome finish; A17734-3,5 Powerboard 1470 antique brass finish).
Contact Customer service from here:
http://www.weiserlock.com/CustomerService/ProductSupport/SupportContact.aspx

Good luck!
0helpful
1answer

Batteries were wearing out and were replaced. Has not worked the same since. Green light on the back continually flashes. When code is entered to unlock sometimes it works on the first try-- sometimes the...

I recommend that you got to this link:

http://www.weiserlock.com/CustomerService/ProductSupport/SupportContact.aspx

and contact Weiser Lock for technical assistance. Yours is an uncommon problem.
0helpful
1answer

Weiser lock began to emit a single long beep at regular intervals of several minutes. Changed the batteries and reset the code and it works fine, however, still continues to emit a single long beep at...

Why is my Powerbolt 1000 unit beeping?

To determine why your lock is beeping abnormally, please follow these steps:

Take out batteries and unplug powerstrip.
Let it sit for 1 minute, then put the batteries back in and wait another minute.
If it does not beep, the keypad needs to be replaced (17733-1).
If the unit continues to beep, the powerboard needs to be replaced (A17734-3,3 Powerboard 1470 brass finish; A17734-3,26D Powerboard 1470 satin chrome finish; A17734-3,5 Powerboard 1470 antique brass finish).

The complete page that I cut this from can be found by cutting and pasting this link into your browser search bar:

http://www.weiserlock.com/Support/Faq/50160000000HhhZAAS.aspx

Since you've already gone through the battery change, this suggests that you need to replace the appropriate Powerboard for your lock.
So this is the link to Weiser Customer Support Page. Here you will find the appropriate contact numbers, US or Canada:

http://www.weiserlock.com/en/CustomerService/ProductSupport/SupportContact.aspx

I suggest calling the appropriate toll-free number and having a conversation with a representative about this problem, first of all to confirm that you need the part before you go through the expense. Secondly, your lock may be new enough for you to talk them into warrantying it, and thirdly, they will be able to get the correct part on order for you.

Good luck!
0helpful
1answer

Powerlock 1000 started beeping! New batteries no help. Won't lock or unlock!

This is the relevant excerpt from the troubleshooting instructions:
Why is my Powerbolt 1000 unit beeping?
To determine why your lock is beeping abnormally, please follow these steps:
  1. Take out batteries and unplug powerstrip.
  2. Let it sit for 1 minute, then put the batteries back in and wait another minute.
  3. If it does not beep, the keypad needs to be replaced (17733-1).
  4. If the unit continues to beep, the powerboard needs to be replaced (A17734-3,3 Powerboard 1470 brass finish; A17734-3,26D Powerboard 1470 satin chrome finish; A17734-3,5 Powerboard 1470 antique brass finish).
Here is the link to the complete instructions:

http://www.weiserlock.com/Support/Faq/50160000000HhhZAAS.aspx

Weiserlock contact information is:

(United States of America) Customer Service Contact Information
Call Us
Toll Free: 800-422-4278 (Mon-Fri, 6:00am - 4:30pm PST)

Good luck!
0helpful
2answers

Does the green light flash all the time on my powerbolt and when I open the door from the outside there is a beeping sound this has never happened before not untill I changed the batterys.

Powerbolt is Beeping?

This is the relevant excerpt from the Powerbolt programming and troubleshooting instructions:



Why is my Powerbolt 1000 unit beeping?

To determine why your lock is beeping abnormally, please follow these steps:

Take out batteries and unplug powerstrip.
Let it sit for 1 minute, then put the batteries back in and wait another minute.
If it does not beep, the keypad needs to be replaced (17733-1).
If the unit continues to beep, the powerboard needs to be replaced (A17734-3,3 Powerboard 1470 brass finish; A17734-3,26D Powerboard 1470 satin chrome finish; A17734-3,5 Powerboard 1470 antique brass finish).

The complete page that I cut this from can be found by cutting and pasting this link into your browser search bar:

http://www.weiserlock.com/Support/Faq/50160000000HhhZAAS.aspx

Since you've already gone through the battery change, this suggests that you need to replace the appropriate Powerboard for your lock.
So this is the link to Weiser Customer Support Page:

http://www.weiserlock.com/en/CustomerService/ProductSupport/SupportContact.aspx

I suggest calling the appropriate toll-free number and having a conversation with a representative about this problem, first of all to confirm that you need the part before you go through the expense. Secondly, they will be able to get the correct part on order for you.

Good luck!
0helpful
1answer

My lock works for awhile then stops. The beeps sound all the time, then stops locking & unlocking using the keypad. Then a day or two it works again.

Here's a link to the Powerbolt 1000 frequently Asked Questions page:

http://www.weiserlock.com/Support/Faq/50160000000HhhZAAS.aspx

You will find this answer on that page:
Why is my Powerbolt 1000 unit beeping?
To determine why your lock is beeping abnormally, please follow these steps:
  1. Take out batteries and unplug powerstrip.
  2. Let it sit for 1 minute, then put the batteries back in and wait another minute.
  3. If it does not beep, the keypad needs to be replaced (17733-1).
  4. If the unit continues to beep, the powerboard needs to be replaced (A17734-3,3 Powerboard 1470 brass finish; A17734-3,26D Powerboard 1470 satin chrome finish; A17734-3,5 Powerboard 1470 antique brass finish).
Not finding what you are looking for?

496 views

Ask a Question

Usually answered in minutes!

Top Weiser Lock Locks & Locksmithing Experts

Sean Wright
Sean Wright

Level 3 Expert

2045 Answers

Cindy Wells

Level 3 Expert

6688 Answers

john h

Level 3 Expert

29494 Answers

Are you a Weiser Lock Lock and Locksmithing Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...