Question about HP Compaq ProLiant DL380 G4 Server

1 Answer

I've added a new HHD to HP 380 G4, but the Windows server 2003 couldn't see it .. then I create a new logic m using array 6i. after that I could t boot from the old HDD .. how can I rollback to the normal state

Posted by yotmano on

Ad

1 Answer

venkatesh kulkarni

  • Level 1:

    An expert who has achieved level 1.

    MVP:

    An expert that got 5 achievements.

    New Friend:

    An expert that has 1 follower.

    Hot-Shot:

    An expert who has answered 20 questions.

  • Contributor
  • 44 Answers

You have removed existing Logical drive and created new one which
made server crash.

Posted on Nov 28, 2011

Ad

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Install new OS


Use the HP Smartstart CD and configure the with array with 2 arrays and 2 logical drives. The first with OS array on RAID 1 (2 drives mirrored). The second array on RAID 5 (3 drives minimum).


http://h20000.www2.hp.com/bizsupport/TechSupport/SoftwareDescription.jsp?lang=en&cc=us&prodTypeId=18964&prodSeriesId=345557&prodNameId=344318&swEnvOID=1005&swLang=8&mode=2&taskId=135&swItem=MTX-bd347636805e4917a617382469


Make sure to use Insight Manager for worry free monitoring.

Oct 22, 2012 | HP ProLiant ML370 G4 Server

1 Answer

Hp proliant dl380 g4 not booting from hard drive


I bought an HP DL380 G4 from here, and called them up any time I had a question like this. These guys were amazingly smart. Perhaps you can call them up and pretend to be a customer?

May 07, 2012 | HP Compaq ProLiant DL380 G4 Server

1 Answer

Hi guies the windows srever 2003 files in my hp ml370 is corrupt and i tried to fix the prblem by format one hard disk partition in my scasi disks array and installing win srv 2003 on it but whe i log on...


HP SmartStart CD x32
The utility to use to set up the ML370 g3 server is the SSCD (smart start cd) this is a guided installation cd that will help you set up the array, install drivers and diagnostic utilities and after that
will request the windows cd so that you can finish the installation.
instructions:
1. download SSCD from here
2. extract the zip file
3. burn the ISO image to a cd
4. boot the server to the cd
5. choose from the main menu the option "Deploy server"
6. follow the wizard

Oct 26, 2010 | HP Compaq ProLiant ML370 G3 Server

1 Answer

I want to install a new scsi but when my os windows small business server 2003 it gives me "setup either detected multiple disk in your machine that are indistinguishable or detected raw disk(s). Setup has...


using the ACU (array configuration utility) create a raid 0 with this drive after the hard drive is being formatted and is configured as raid 0 (no redundant) restart the server and the hard drive should be detected as a new logical volume with a assigned letter "D" "E"
ACU

Jul 30, 2010 | HP ProLiant ML370 G3 Server

1 Answer

I have a HP DL 380 server and its configured as domain controler.... and has a raid5 configration .while we are woking it makes a restart and when its restarted windows was unable to boot asking for NTLDLR...


Are you able to get into the array configuration and make sure the logical drive is still intact? If the logical drive is gone, then your partition may be lost. If you are able to recover the logical drive in your array (which you should be able to if the RAID5 striping was stable) then you should be able to recover your data. You can get into the array configuration during the boot up sequence.

Jan 06, 2009 | HP Compaq ProLiant DL380 G4 Server

3 Answers

Drive array problem


Hi Nick ,

As of now you can Select "F2" to accept data loss and re-enable logical drive. This Load OS Normally .
It seems that one of the HDD in the RAID 5 has failed , Did you notice any LED indications like red or amber on the HDDs ?? if so get that hdd replaced . Make sure the Failed HDD is replaced .
You can run the Array Diagnostic Utility from HP System tools to check the Failed Drives and also frimware version of the controller . If the frimware is not latest Update it from HP website. DL380 G4 should have Smart Array 6i controller .

Hope This was Helpful
cheers :)

May 17, 2008 | HP Compaq ProLiant DL380 G4 Server

1 Answer

Problem with DL380 G4 after reboot


do you use software/hardware raid?
hopefully hardware :-)
and is it mirrord or raid5?

Jan 26, 2008 | HP Compaq ProLiant DL380 G4 Server

1 Answer

Problem with new array.


Do you see your new disk in the "Disk Management" window? To get there go to "run", type "compmgmt.msc", then click disk management. If you do see the disks there, then you need to format the disk to a "basic" configuration. If your new disk/volume does not show up there, I would suggest a hard reset on your server whenever possible. I see this issue at times with Windows and newly added storage array logical drives.

Aug 31, 2007 | IBM Total Storage DS400 (13n1777) Fibre...

Not finding what you are looking for?
HP Compaq ProLiant DL380 G4 Server Logo

Related Topics:

110 people viewed this question

Ask a Question

Usually answered in minutes!

Top HP Computers & Internet Experts

Lee Hodgson
Lee Hodgson

Level 3 Expert

4810 Answers

Muntejaya Ginting
Muntejaya Ginting

Level 3 Expert

10422 Answers

efs_perpends
efs_perpends

Level 3 Expert

1997 Answers

Are you a HP Computer and Internet Expert? Answer questions, earn points and help others