Bryant 463AAC005BA Air Conditioner Logo

Related Topics:

Posted on Jun 12, 2011

I have a Godrej Split AC, and water is leaking from my Indoor unit . I have cleaned the pipe through which the water drains out , but still water in leaking from indoor unit.The water starts flowing , 2 hour later from the time the AC is switched on . Few things to notice : a) After cleaning the drain pipe , the flow water draining from the pipe is drop b drop b) Once is tried to give a tilt to the AC and all the water collected drained down the wall inside the room,and during that time the flow of water also increased to some extent i the drain pipe Kinldy help me to fix this problem

5 Related Answers

Anonymous

  • 958 Answers
  • Posted on Sep 13, 2008

SOURCE: Mitsubishi Mr. Slim Mini Split MS-A12WA Indoor Unit

no sir gary,

the water would not go to the drain pan if you install it vertically.

water would just drop anywhere and would ruin a lot of things...
'

tnx 4 using fixya,

drcool

Ad

Anonymous

  • 76 Answers
  • Posted on Oct 22, 2008

SOURCE: York Mini-Split Not Cooling? : (

This can only be a gas problem.
the split units goes on on and off if a shortage of gas is involved, the chances that you would here it wont be that big for the fans would make too much noise.
get a repair man for a re gas and all is well.

Good luck.

Wouter.

Anonymous

  • 1 Answer
  • Posted on Apr 25, 2009

SOURCE: ac split unit indoor an ouydoor unit electrical wiring diagram

machine off

jmgldsmth

Jim Goldsmith

  • 2005 Answers
  • Posted on May 28, 2009

SOURCE: ice formation in the indoor unit

you need to have the unit checked for the amount of freon in the system this must be done with a gauge set the freon amount is obviously incorrect
also the a-frame evaporator must be sealed in the furnace cabinet

Anonymous

  • 4090 Answers
  • Posted on Aug 02, 2009

SOURCE: LG split (3 indoor) LMU360CE

02 Indoor In-Piping Error 2 times OFF

There is a complete guikde to problems on page 66 of users manual. If you dont have one get back to me with your email.

Ad

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer

Unit is leaking water from the back against the wall It is a split unit AC Drainpipe and filters are clean

check for a moss type blockage at the end of the drain trough that the drain pipe connects to
it is under the evaporator fins at the back at is at the end where the drain pipe connects to
0helpful
1answer

Why does my split ac unit leak inside the house?

This happens when the drain pipe is too high, or kinked. The pipe must be lower then the drain pan in order for the water to drain. This is a common problem.
2helpful
1answer

Water leaking from the indoor unit of my split type ac

dear sir

i think there is in indoor unit filter is dirty it,s need to clean and after reinstall there . water drain hose/pipe is block it.s need to clean.i hope after that your problem will be solve .

hope answer the question
thank you
please vote!
0helpful
2answers

Water drops are flowing in the indoor unit of samsung split ac. It is happening from the date of installation. There is no dirt block in drain pipe or the filter. Water coming from the drain pipe is small...

I feel the water drops are condensation caused by cold air when its warm weather. There should be a catch basin to catch it and it should dry itself out in a while if not is there any place you can put one in yourself. Maybe just wrapping the pipe with a towel could help. the pipe is cold and it could cause water to form. I would try to insulate the pipe with pipe wrap. You can buy it at a hardware store. See what happens.
0helpful
1answer

I have problem regarding water tapping in indoor unit of split a.c.

dear sir /madam
please do every week clean your split type a/c,s filter it,s main coz who responsible for block the drain water line and after that split indoor drain ac unit drain water from inside of the unit , try to find out the drain water line of indoor unit of air conditioner the make clean it and also check it i mean keep some fresh water for make test its drain line it have been open or not if water is going easily then ,it,s ok
it,s up tp you if you think you can do it or contact to it,s technician for do solve this problem.

thank you for using fixya for get solution
hope answer the question
please vote!
0helpful
1answer

Water leaking from indoor unit against the wall.

It's probably the insulation around your refrigerant pipes. If it is too thin or missing in a section they will condensate.
3helpful
2answers

Water leakage from internal unit of split AC

Draim pans do get dirty and partialy block drain pan. If possible take a shop vac and gently **** out the drain line. This will pull the restriction out of the line and help clean drain pan. Rusty
5helpful
2answers

Split System Air conditioner

There normally two types of leakages from the wall unit.
1.The warm air in the room when comes in contact with the cooling coil of heat exchanger (consisting of fine fins where compressed refrigerant evaporates) looses its heat & cannot retain the same moisture content at lower temperature at the point of contact with evaporator. There is a provision of a drain pipe to carry this condensed water to outside water drain. So if the drain pipe is choked or the coupling joint of the drain pipe at the bottom of cooling coil is not proper, there will be water leakage, This can be easily attended by physically looking at the fittings.
2.The second problem can be the leakage of the refrigerant. If there is second type of problem, then there will be very little or no cooling irrespective of continuous running of air conditioner. This can be easily checked by feeling the temperature of outlet air from the air conditioner.

Conclusion-As you have written that there is leakage from the air conditioner, but you have not written whether it is visible or invisible. If the leakage is visible, it is problem number 1 & if it is invisible, it is problem number 2.

If you are not satisfied you are free to ask for more explanations.
1helpful
1answer

LG LST243C-2

- Check your air filter at the indoor if clean.
- Check your evaporator fins if clean.
- Check if no icing in your evaporator and outdoor pipes.
- If your air filter and evaporator fins is clean and icing is present then your unit is under charge.
- When your indoor drips check your drain pipe if there are water comes out. If no water drain from your drain pipes then your drainage is restricted.
- Flush your drainage with water using your garden hose to flush out dirts from your drainage.
9e8d6f3.jpg





cca6163.jpg
Not finding what you are looking for?

1,739 views

Ask a Question

Usually answered in minutes!

Top Bryant Heating & Cooling Experts

john h

Level 3 Expert

29494 Answers

vince

Level 3 Expert

2530 Answers

Cindy Wells

Level 3 Expert

6688 Answers

Are you a Bryant Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions