Question about Microwave Ovens

Open Question

Sharp R-957 Microwave cutting out after 59 seconds

The microwave only works for 59 secs regardless which setting you use it on. Anyone know how to repair this please?

Posted by reesm on

Ad

5 Related Answers

MicrowaveSvc

William Miller

  • 9179 Answers

SOURCE: Our sharp 957 will now

This is a problem in one of the damper-related components, most likely the switch, but it may also be the motor or the damper door.

This is also likely why your convection mode stopped working.

The damper is a door inside that opens or closes depending on cooking mode. If the controller senses that the door is not in the right position, it will shut down the cook cycle.

Sharp models stop after 59 seconds.

See the attached sample photo for a typical damper assembly.

Info on ordering Sharp UK parts / spares is here.

We're happy to help you with free advice and we'd appreciate your thoughtful rating of our answer.

0926a02.jpg

Posted on Sep 27, 2008

Ad
MicrowaveSvc

William Miller

  • 9179 Answers

SOURCE: Sharp model R-1870 Carosel quits cooking at 59 seconds

This is a problem in one of the damper-related components, most likely the switch, but it may also be the motor or the damper door.

The damper is a door inside that opens or closes depending on cooking mode. If the controller senses that the door is not in the right position, it will shut down the cook cycle.

Sharp models stop after 59 seconds.

See the attached sample photo for a typical damper assembly.

We have the applicable service manuals for these models and have uploaded it to our site here and here to help you. You will need the free Adobe Reader to view or print it.

If a switch is all you need, we offer a universal type for only $5 postpaid which you can order here.

We're happy to help you with free advice and we'd appreciate your thoughtful rating of our answer.

Posted on Jan 29, 2009

Ad
MicrowaveSvc

William Miller

  • 9179 Answers

SOURCE: Sharp R-1870 stops at 59 seconds

Wow. I just read something ridiculous!

Well, never mind that, here's your solution:

This is a common problem in one of the damper-related components, most likely the switch, but it may also be the motor or the damper door.

The damper is a door inside that opens or closes depending on cooking mode. If the controller senses that the door is not in the right position, it will shut down the cook cycle.

Sharp models stop after 59 seconds.

See the attached sample photo for a typical damper assembly.

We have the applicable service manuals for these models and have uploaded it to our site here and here to help you. You will need the free Adobe Reader to view or print it.

If a switch is all you need, we offer a universal type for only $5 postpaid which you can order here.

We're happy to help you with free advice and we'd appreciate your thoughtful rating of our answer.

Posted on Jan 29, 2009

MicrowaveSvc

William Miller

  • 9179 Answers

SOURCE: Sharp model R-1871 shuts off every 59 seconds

This is a problem in one of the damper-related components, either the switch or motor or the damper door may be binding.

The damper is a door inside that opens or closes depending on cooking mode. If the controller senses that the door is not in the right position, it will shut down the cook cycle.

Sharp models stop after 59 seconds.

See the attached sample drawing for a typical damper assembly.

We have the applicable service manuals for these models and have uploaded it to our site here and here to help you.

If a switch is all you need, we offer a universal type for only $5 postpaid which you can order here.

We're happy to help you with free advice and we'd appreciate your thoughtful rating of our answer.

William E. Miller
[email protected]
http://www.microwavedisplay.com

b27054b.jpg

Posted on Aug 30, 2009

Testimonial: "traced to motor for damper. Would not have had a clue without this information provided by fixya"

David Hanks

  • 178 Answers

SOURCE: Amana OTR Convection Microwave runs 59 seconds and shuts off

This sounds like either a thermistor or a damper switch/motor problem.
Amana's technical support line is 866-426-2621. This is the commercial side but they should be able to get you in touch with the domestic side.

Posted on Sep 12, 2009

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

The microwave stops itself everytime at 59 secs if put on for any time over a minute


Change the damper motor and switch. Cost for both approx. $30.00. Must remove cover to gain access to motor & switch.
ZephyrKnight

Feb 17, 2011 | Sharp Microwave Oven Microwave Oven

1 Answer

Stops every 59 sec.


This is a problem in one of the damper-related components, either the switch or motor or the damper door may be binding.

The damper is a door inside that opens or closes depending on cooking mode. If the controller senses that the door is not in the right position, it will shut down the cook cycle.

Sharp models stop after 59 seconds. That's the giveaway.

See the attached sample drawing for a typical damper assembly.

We have the applicable service manuals for some of these models and have uploaded them to our site here and here to help you.

Hopefully these cover your model number, which you didn't mention.

If a switch is all you need, we offer a universal type for only $5 postpaid which you can order here.

We're happy to help you with free advice and we'd appreciate your thoughtful rating of our answer.

William E. Miller
[email protected]
http://www.microwavedisplay.com

d34621a.jpg

Jul 07, 2010 | Sharp R-1870 Convection/Microwave Oven

1 Answer

I have a sharp microwave mod.#r-1870 you can set it for 5 mins.it will run 59 sec.then shut down you start it right back and it will run 59 sec. and shut down again.


i think there are some problem occured with the autocut n timer....its a genuine prob go to any electrician...thnx

Feb 26, 2010 | Microwave Ovens

1 Answer

GE Spacemaker JVM 1631: Starts working and stops 3 sec later??


your magnetron is leaking RF do not use until you replace the magnetron, it is interfering with the pc board

Feb 05, 2010 | GE JVM1631 Microwave Oven

2 Answers

Sharp R-1870 stops at 59 seconds


Wow. I just read something ridiculous!

Well, never mind that, here's your solution:

This is a common problem in one of the damper-related components, most likely the switch, but it may also be the motor or the damper door.

The damper is a door inside that opens or closes depending on cooking mode. If the controller senses that the door is not in the right position, it will shut down the cook cycle.

Sharp models stop after 59 seconds.

See the attached sample photo for a typical damper assembly.

We have the applicable service manuals for these models and have uploaded it to our site here and here to help you. You will need the free Adobe Reader to view or print it.

If a switch is all you need, we offer a universal type for only $5 postpaid which you can order here.

We're happy to help you with free advice and we'd appreciate your thoughtful rating of our answer.

Jan 26, 2009 | Sharp R-1480 Microwave Oven

1 Answer

Sharp model R-1870 Carosel quits cooking at 59 seconds


This is a problem in one of the damper-related components, most likely the switch, but it may also be the motor or the damper door.

The damper is a door inside that opens or closes depending on cooking mode. If the controller senses that the door is not in the right position, it will shut down the cook cycle.

Sharp models stop after 59 seconds.

See the attached sample photo for a typical damper assembly.

We have the applicable service manuals for these models and have uploaded it to our site here and here to help you. You will need the free Adobe Reader to view or print it.

If a switch is all you need, we offer a universal type for only $5 postpaid which you can order here.

We're happy to help you with free advice and we'd appreciate your thoughtful rating of our answer.

Jan 26, 2009 | Sharp R-1480 Microwave Oven

5 Answers

Shuts down after 59 sec


Chances are you have a bad damper switch or wiring. A sample photo is here: http://207.234.249.73/mwd/damper.jpg It might also be a problem with the humidity sensor or a problem with the control panel, such as corrupted code or bad connections.

Dec 20, 2006 | Sharp R-1850A Convection/Microwave Oven

Not finding what you are looking for?
Microwave Ovens Logo

Related Topics:

103 people viewed this question

Ask a Question

Usually answered in minutes!

Top Microwave Ovens Experts

William Miller
William Miller

Level 3 Expert

9179 Answers

Marvin
Marvin

Level 3 Expert

85239 Answers

Cindy Wells

Level 3 Expert

6099 Answers

Are you a Microwave Oven Expert? Answer questions, earn points and help others