Ac unit central

Wont turn off by its self on auto. somtimes blower wont work, everything works fine outside. GOODMAN UNIT can some one help please? can you tell me the conection to the water pump, what wires it goes to, now it is connected to red to thermosted and red to circuit board thats one wire. the other wire from pump is connnected to white from themosted and white from circuit board. the white , red and green wires from circuit board go to what other wires. capasitor from compressor outsibe maybe?
thanks you all.

Posted by QVO_SAT on

Ad

1 Answer

Anonymous

  • Level 2:

    An expert who has achieved level 2 by getting 100 points

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

    Prodigy:

    An expert who has answered 500 questions.

  • Expert
  • 540 Answers

Sorry, we don't have water cois in our area.

Posted on Aug 21, 2008

Ad

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Myblowermotor on my goodman furnace will only work when the heat is turned on when i turn on the ac the blower motor wont kick on but the the ac unit turns on i can here the outside unit working


Is this a new tstat? How about trying cooling with fan in on position , what happens? What is the model number of your indoor unit please.

If you need further help, reach me via phone at https://www.6ya.com/expert/thomas_092728000e6acb79

May 25, 2018 | Goodman Heating & Cooling

1 Answer

I have a Goodman CPE30-1AB (Outside heat exchanger), with a Goodman (air blower) as well. Air blows inside, but not cold. Outside unit is not turning on at all. Can you please assist?


check your breaker or fuses at outside unit. verify you have 24 volts feeding outside unit replace outside unit contactor if you have the 24 volts and not starting.

Aug 08, 2015 | Goodman Heating & Cooling

1 Answer

Noise on high speed


Is it the original size motor? It sounds like it could be to many CFM for the size of the duct causing back pressure when the blower goes into high.

Apr 08, 2014 | Goodman Manufacturing Goodman MBVC2000AA...

1 Answer

I have a goodman cpk j42 -1b ac unit on the outside and a central heat and air unit inside. the ac unit come on and runs fine but when it hit the temp the thermastat clicks and the fan outside goes of but...


Hello BWOOD Check the thermostat FAN button is in AUTO position not ON position.That might be it .The relay is in the blower unit but they RARELY become frozen/welded stuck on.

Aug 30, 2010 | Heating & Cooling

1 Answer

Hi, just replaced the capacitor thinking that would solve the problem but it appears it did not. The motor outside would kick on the unit inside would kick on but the blower motor inside works sometimes...


Turn off the power to the air handler(indoor unit). Remove the access panel. From the motor,trace the wires back to the fan relay. One wire will probably trace back to the incoming power terminal. The other is the fan relay. It could be intermittent thermostat signal to the relay or a bad relay.
To verify if the fan motor is good,you can remove the one wire from the relay and re-attach it to the other side of the incoming power terminal. If it runs OK there,replace the relay. If it does not run,replace the blower motor.

Sep 28, 2009 | Heating & Cooling

1 Answer

AC unit turns on blower doesn't come on


The thermostat is the controller.

Jun 19, 2009 | Heating & Cooling

1 Answer

Goodman AR42-1 blower works on heat mode but not on a/c


You may have a problem with the board or the motor, as there is a separate speeds for heating and cooling. I would call a competent, NATE certified technician to daignose this properly.

Jan 03, 2009 | Goodman GMS90703BXA Heater

3 Answers

Blower fan keeps shutting on/off,


Your blower fan turning on and off shows your thermostat is working. I am willing to bet you have the fan in the automatic condition. Check for a sticking contactor at the outside unit.

May 31, 2008 | Heating & Cooling

Not finding what you are looking for?
Goodman CLQ36AR49 Air Conditioner Logo

79 people viewed this question

Ask a Question

Usually answered in minutes!

Top Goodman Heating & Cooling Experts

Paul Carew

Level 3 Expert

3510 Answers

Brad Scarpetta

Level 2 Expert

104 Answers

Tom Palicke

Level 1 Expert

47 Answers

Are you a Goodman Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...