I have a great lakes hot tub. The control panel has the following buttons. jets.temp.light. The motor is pulsating. if I hold down the light switch the motor runs normal. I release it pulsates. Jet button does not seem to work. 4 years old first time problem.

Posted by evanstim8 on

Ad

3 Related Answers

Dale Cobb

  • 366 Answers

SOURCE: I have a 2004 great lakes hot tub with a balboa

check to see that the flow switch is working properly, it may not have enough flow on low speed to allow the heater to turn on. Make sure your filter/s is/are clean. If you have a pressure switch instead of a flow switch, it may need to be adjusted or replaced.

Posted on Feb 09, 2010

Ad
Ian  Hot Tub

Ian Kime

  • 77 Answers

SOURCE: Error code reads

'Sn' is a general error message relating to the temperature sensors.

Assuming that you have a Balboa spa pack (M7 version), turn off the power and remove the spa pack cover, you'll find two temperature sensors mounted in the top of the heater tube one at each end. Follow the wiring from the sensor to the plug(s) on the PCB and check that the connections are good, they have a habit of devekoping a poor connection.

If you have a multimeter you could also check the resistance of the two sensors. They should both be the same. If they aren't the same you'll probably have to replace them.

One final thing just to check... Ensure that there are no blockages within the heater. Unless you have service/gate valves you will have to drain the hot tub, unscrew the unions and check inside the heater for debris within the heater assembly.

If you're from the UK I may be able to help regarding parts etc.

Kind Regards,
Ian.
http://hottub.synthasite.com

Posted on Apr 08, 2010

Ad
adamh294

adam hudson

  • 310 Answers

SOURCE: i have a great lakes

The topside control manuals are paired with the main Spa Pack control system. If you email me the model information off of your spa pack, I can help you to find your manual.

[email protected]

Posted on Jun 14, 2011

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

The power went out in town, the power came back on, and the power is on to the hot tub, but we got an F2 code, and it isn't going on to cycle and the temp is at 54 now. What is the F2 code. We have a great...


I need to know what kind of control pack your tub has. If you can open the side panel and tell me what brand the pack is I can tell you what the error code is for.

Nov 03, 2013 | Qca Spas Dream Series Dream Master Hot Tub...

1 Answer

My pacific hot tub has LOC on the display and i cant adjust the jets or temp. Is the display locked and how do i unlock it?


Mike,

Yes LOC is a standard topside lock code.

Try these common unlock codes,

Press & Hold Jet Button for 6 seconds
or
Press & Hold Temp Up & Temp down for 6 seconds.

Possibly your jet button is faulty i.e. it is broken internally or when it is pressed the button sticks in the on position and locks out the panel.

If those common codes don't work let me know which brand/topside control your spa has and I will get a more specific answer.

Jan 16, 2012 | Pool & Spa

1 Answer

I have a hydroquip hot tub heater system. Everything works great but no heat. Heater indicator light does not come on. Just replaced the pressure switch, & still no heat. The heat light on topside con


Bad heating element. Shut the power to the breaker off, disconnect the wires off of the heating element and then check for (ohms) continuity across the two element leads. If it show OL on the meter then you here is an open in the element and it will need to be replaced. Good luck.

Oct 04, 2017 | Pool & Spa

2 Answers

Hot tub stuck in 'SL' mode


Need to know what buttons your topside control has... depending on the model, some have a mode button which you press and release and then immediately press the temp up or down, to select SL for sleep (no heat), ST for standard (heat as needed) or EC for Economy (only heat during filtration). If the mode button is not present, and you have a single temp button and light button, try pressing and releasing temp and then immediately pressing light button, repeat until choice appears, then wait, it will hold last displayed mode.

Jul 09, 2010 | Jacuzzi Balboa R574 System for 1 2 Speed...

1 Answer

We have a Great Lakes spa with a Balboa control panel, manufactured in 1992. When you plug the spa in, it will shut down and read Sn on the topside control panel. We have replaced the high limit/temp...


Contact Balboa's Customer support department directly at 800-645-3201, follow the prompts to customer tech support (or press 0 and ask for customer support). You will need to be at the spa, control panel open and ready to read off the chip number, and you will need to be proficient with a test meter (AC voltage). The SN error is related to a bad sensor(s), but can also indicate a failed board. An incorrect sensor set will also create this problem, so confirm you used the exact or compatible replacement. If the SN code issue is no longer a problem, but the spa is still not heating, look and see if the heater led is on. If it is, you likely have some burned relays on the board, which can be replaced cheaper than replacing the board. If you need more help, email me at [email protected]

Jun 12, 2010 | Pool & Spa

1 Answer

I have a 2004 great lakes hot tub with a balboa controler. My hot tub heats up fine when the pump runs on high but the temp light never comes on when the pump runs in low.


check to see that the flow switch is working properly, it may not have enough flow on low speed to allow the heater to turn on. Make sure your filter/s is/are clean. If you have a pressure switch instead of a flow switch, it may need to be adjusted or replaced.

Feb 04, 2010 | Qca Spas Jewel Series Topaz Plus Hot Tub

2 Answers

How to Get Hot tub off sleep mode


press temp button and then the light button in sequence.

Nov 14, 2009 | Jacuzzi Balboa R574 System for 1 2 Speed...

2 Answers

Reset error code hot tub


tub is in sleep mode usually to change u must press temp button then light button you want to b on standard mode STD

Oct 04, 2009 | Qca Spas Dream Series Dream Master Hot Tub...

Not finding what you are looking for?
Qca Spas Dream Series Dream Master Hot Tub with Flex Cover Logo

Related Topics:

1,357 people viewed this question

Ask a Question

Usually answered in minutes!

Top Qca Spas Pool & Spa Experts

Brad Brown

Level 3 Expert

18520 Answers

john h

Level 3 Expert

23504 Answers

Gene Haynes

Level 3 Expert

5391 Answers

Are you a Qca Spas Pool and Spa Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...