Question about Sony FD Trinitron WEGA KV-32FS120 32" TV
Nine blinks - Indication of shorted/leaky diodes - D6116 and D6301 on the "G"
board. Panel
Module Error or Thermal Error. Unless you are technically experienced, this can only be repaired by an authorised service centre. Obtain a quote for this, the parts are inexpensive, but labour costs might not be.
If it is intermittent 9 blinks, meaning
sometimes the TV comes on and other times you get flashing, then change
the switching IC regulator on the "G" board or check connections. Make sure
the regulator is -12V or -13V (negative rail).
If the repair is done by an approved workshop, they will clear the error codes (standby LED blinks) as part of their 'soak-testing' and it should reset the TV back to factory condition. Remember to ask about what work was done and if the errors have been cleared/reset before you pay their bill.