Refrigerators Logo
Anonymous Posted on Feb 16, 2011

Refridgerator not cooling. Replaced defrost board. Snapping or popping noise heard underneath or behind.

1 Answer

Anonymous

Level 3:

An expert who has achieved level 3 by getting 1000 points

Superstar:

An expert that got 20 achievements.

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

  • Maytag Master 43,501 Answers
  • Posted on Feb 16, 2011
Anonymous
Maytag Master
Level 3:

An expert who has achieved level 3 by getting 1000 points

Superstar:

An expert that got 20 achievements.

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Joined: Nov 12, 2009
Answers
43501
Questions
0
Helped
10843691
Points
101584

Hi,

Defrost coils are bad and burn out board...
Check out these tips...they can help you figure out what is going wrong with your refrigerator and why it is not cooling

Refrigerator not Cooling or Fridge not Cooling

How to Defrost Refrigerator
Defrost Timer Problem

Water Running in refrigerator from Freezer


Refrigerator or Freezer not Cooling or Getting Cold


heatman101

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1helpful
1answer

My Amana refridgerator does not cool but the freezer works

If you have noticed a rise in temperature in the fridge, and there seems to be fromst building up in the freezer than your problem is one or more parts of the defrost system is malfunctioned and in return your problem arises. There are three parts to the system, the defrost timer or in some cases control board, defrost thermostat also known as a bi-metal, and the defrost heater. The defrost system is set up to operate as so. The defrost timer or control board will turn the machine off, in some cases every 8 hours, some 12. During this time period the defrost heaters, located behind the freezer wall and rest underneath the evaporator, yet wires to them run up the side of it, are energized and emit heat that raises upward to melt the ice that has formed on the evaporator coils. The bi-metal or defrost thermostat is at the top of the evaporator. When the heat from the heater starts to reach the bi-metal, it breaks the circuit turning the heater off. The whole purpose of this is because the freezer cool the refridgerator side by drawing air across the coils and blowing to the other side via the evap fan motor. In my opinion, if you change one part of the defrost system change them all because usually when one part fails another will follow, so save yourself the time and the food loss, the cost difference is minute.

If you need further help, I’m available over the phone at https://www.6ya.com/expert/jason_4570d45317834dd3

0helpful
1answer

Maytag side by side fridge MSD2351HEW has frost buildup on freezer side at top and making noise

If you have noticed a rise in temperature in the fridge, and there seems to be fromst building up in the freezer than your problem is one or more parts of the defrost system is malfunctioned and in return your problem arises. There are three parts to the system, the defrost timer or in some cases control board, defrost thermostat also known as a bi-metal, and the defrost heater. The defrost system is set up to operate as so. The defrost timer or control board will turn the machine off, in some cases every 8 hours, some 12. During this time period the defrost heaters, located behind the freezer wall and rest underneath the evaporator, yet wires to them run up the side of it, are energized and emit heat that raises upward to melt the ice that has formed on the evaporator coils. The bi-metal or defrost thermostat is at the top of the evaporator. When the heat from the heater starts to reach the bi-metal, it breaks the circuit turning the heater off. The whole purpose of this is because the freezer cool the refridgerator side by drawing air across the coils and blowing to the other side via the evap fan motor. In my opinion, if you change one part of the defrost system change them all because usually when one part fails another will follow, so save yourself the time and the food loss, the cost difference is minute.

If you need further help, I’m available over the phone at https://www.6ya.com/expert/jason_4570d45317834dd3

0helpful
1answer

Frigidaire Refridgerator not cooling. Worked for about 2 weeks after replacing defroster

The first thing you want to do is open the freezer and see if the fan inside there is running. The reason is the freezer cools the refrigerator side by circulating air from the freezer. If the fan is running then your problem is one or more parts of the defrost system is malfunctioned and in return your problem arises. There are three parts to the system, the defrost timer or in some cases control board, defrost thermostat also known as a bi-metal, and the defrost heater. The defrost system is set up to operate as so. The defrost timer or control board will turn the machine off, in some cases every 8 hours, some 12. During this time period the defrost heaters, located behind the freezer wall and rest underneath the evaporator, yet wires to them run up the side of it, are energized and emit heat that raises upward to melt the ice that has formed on the evaporator coils. The bi-metal or defrost thermostat is at the top of the evaporator. When the heat from the heater starts to reach the bi-metal, it breaks the circuit turning the heater off. The whole purpose of this is because the freezer cool the refridgerator side by drawing air across the coils and blowing to the other side via the evap fan motor. In my opinion, if you change one part of the defrost system change them all because usually when one part fails another will follow, so save yourself the time and the food loss, the cost difference is minute

If you need further help, I’m available over the phone at https://www.6ya.com/expert/jason_4570d45317834dd3

0helpful
1answer

Freezer works refridgerator dont

The first thing you want to do is open the freezer and see if the fan inside there is running. The reason is the freezer cools the refrigerator side by circulating air from the freezer. If the fan is running then your problem is one or more parts of the defrost system is malfunctioned and in return your problem arises. There are three parts to the system, the defrost timer or in some cases control board, defrost thermostat also known as a bi-metal, and the defrost heater. The defrost system is set up to operate as so. The defrost timer or control board will turn the machine off, in some cases every 8 hours, some 12. During this time period the defrost heaters, located behind the freezer wall and rest underneath the evaporator, yet wires to them run up the side of it, are energized and emit heat that raises upward to melt the ice that has formed on the evaporator coils. The bi-metal or defrost thermostat is at the top of the evaporator. When the heat from the heater starts to reach the bi-metal, it breaks the circuit turning the heater off. The whole purpose of this is because the freezer cool the refridgerator side by drawing air across the coils and blowing to the other side via the evap fan motor. In my opinion, if you change one part of the defrost system change them all because usually when one part fails another will follow, so save yourself the time and the food loss, the cost difference is minute.

If you need further help, I’m available over the phone at https://www.6ya.com/expert/jason_4570d45317834dd3

0helpful
1answer

Ice continues to build up on the cooling unit behind a panel in the back of the freezer. Why?

The first thing you want to do is open the freezer and see if the fan inside there is running. The reason is the freezer cools the refrigerator side by circulating air from the freezer. If the fan is running then your problem is one or more parts of the defrost system is malfunctioned and in return your problem arises. There are three parts to the system, the defrost timer or in some cases control board, defrost thermostat also known as a bi-metal, and the defrost heater. The defrost system is set up to operate as so. The defrost timer or control board will turn the machine off, in some cases every 8 hours, some 12. During this time period the defrost heaters, located behind the freezer wall and rest underneath the evaporator, yet wires to them run up the side of it, are energized and emit heat that raises upward to melt the ice that has formed on the evaporator coils. The bi-metal or defrost thermostat is at the top of the evaporator. When the heat from the heater starts to reach the bi-metal, it breaks the circuit turning the heater off. The whole purpose of this is because the freezer cool the refridgerator side by drawing air across the coils and blowing to the other side via the evap fan motor. In my opinion, if you change one part of the defrost system change them all because usually when one part fails another will follow, so save yourself the time and the food loss, the cost difference is minute.

If you need further help, I’m available over the phone at https://www.6ya.com/expert/jason_4570d45317834dd3

0helpful
1answer

Fridge not cooling freezer is

Your problem is one or more parts of the defrost system is malfunctioned and in return your problem arises. There are three parts to the system, the defrost timer or in some cases control board, defrost thermostat also known as a bi-metal, and the defrost heater. The defrost system is set up to operate as so. The defrost timer or control board will turn the machine off, in some cases every 8 hours, some 12. During this time period the defrost heaters, located behind the freezer wall and rest underneath the evaporator, yet wires to them run up the side of it, are energized and emit heat that raises upward to melt the ice that has formed on the evaporator coils. The bi-metal or defrost thermostat is at the top of the evaporator. When the heat from the heater starts to reach the bi-metal, it breaks the circuit turning the heater off. The whole purpose of this is because the freezer cool the refridgerator side by drawing air across the coils and blowing to the other side via the evap fan motor. In my opinion, if you change one part of the defrost system change them all because usually when one part fails another will follow, so save yourself the time and the food loss, the cost difference is minute.

If you need further help, I’m available over the phone at https://www.6ya.com/expert/jason_4570d45317834dd3

0helpful
1answer

Fridge froze over on back wall now not cooling

Your problem is one or more parts of the defrost system is malfunctioned and in return your problem arises. There are three parts to the system, the defrost timer or in some cases control board, defrost thermostat also known as a bi-metal, and the defrost heater. The defrost system is set up to operate as so. The defrost timer or control board will turn the machine off, in some cases every 8 hours, some 12. During this time period the defrost heaters, located behind the freezer wall and rest underneath the evaporator, yet wires to them run up the side of it, are energized and emit heat that raises upward to melt the ice that has formed on the evaporator coils. The bi-metal or defrost thermostat is at the top of the evaporator. When the heat from the heater starts to reach the bi-metal, it breaks the circuit turning the heater off. The whole purpose of this is because the freezer cool the refridgerator side by drawing air across the coils and blowing to the other side via the evap fan motor. In my opinion, if you change one part of the defrost system change them all because usually when one part fails another will follow, so save yourself the time and the food loss, the cost difference is minute.

If you need further help, I’m available over the phone at https://www.6ya.com/expert/jason_4570d45317834dd3

0helpful
1answer

Have an amana freezer on bottom, refrigerater is not cooling but I noticed some frost buildup in the freezer unit

Your problem is one or more parts of the defrost system is malfunctioned and in return your problem arises. There are three parts to the system, the defrost timer or in some cases control board, defrost thermostat also known as a bi-metal, and the defrost heater. The defrost system is set up to operate as so. The defrost timer or control board will turn the machine off, in some cases every 8 hours, some 12. During this time period the defrost heaters, located behind the freezer wall and rest underneath the evaporator, yet wires to them run up the side of it, are energized and emit heat that raises upward to melt the ice that has formed on the evaporator coils. The bi-metal or defrost thermostat is at the top of the evaporator. When the heat from the heater starts to reach the bi-metal, it breaks the circuit turning the heater off. The whole purpose of this is because the freezer cool the refridgerator side by drawing air across the coils and blowing to the other side via the evap fan motor. In my opinion, if you change one part of the defrost system change them all because usually when one part fails another will follow, so save yourself the time and the food loss, the cost difference is minute.

If you need further help, I’m available over the phone at https://www.6ya.com/expert/jason_4570d45317834dd3

2helpful
1answer

Every few days the freezer side of a side-by-side refrigerator freezes over (ice on coils), while the refrigerator side is warm. The thermostat has been replaced, but problem continues. Any troubles

Your problem is one or more parts of the defrost system is malfunctioned and in return your problem arises. There are three parts to the system, the defrost timer or in some cases control board, defrost thermostat also known as a bi-metal, and the defrost heater. The defrost system is set up to operate as so. The defrost timer or control board will turn the machine off, in some cases every 8 hours, some 12. During this time period the defrost heaters, located behind the freezer wall and rest underneath the evaporator, yet wires to them run up the side of it, are energized and emit heat that raises upward to melt the ice that has formed on the evaporator coils. The bi-metal or defrost thermostat is at the top of the evaporator. When the heat from the heater starts to reach the bi-metal, it breaks the circuit turning the heater off. The whole purpose of this is because the freezer cool the refridgerator side by drawing air across the coils and blowing to the other side via the evap fan motor. In my opinion, if you change one part of the defrost system change them all because usually when one part fails another will follow, so save yourself the time and the food loss, the cost difference is minute.
Defrost timer pt# 215846602
Defrost heater pt # 218169802
Defrost thermostat pt # 297216600

If you need further help, I’m available over the phone at https://www.6ya.com/expert/jason_4570d45317834dd3

0helpful
2answers

Won't freeze on freezer side ( defrosting) and won't get cold on refridgerator side

If you have confirmed that the unit is defrosting and the freezer isn't getting cold. Make sure underneath the refrigerator is completely clean and the fan is running underneath the refrigerator next to the coils. If this all checks out then you have a bad compressor or lost of refrigerant due to a leak in the system. One last thing: Is the cooling fan running in the freezer?

Not finding what you are looking for?

115 views

Ask a Question

Usually answered in minutes!

Top Maytag Refrigerators Experts

vince

Level 3 Expert

2530 Answers

Johnny 1000

Level 2 Expert

94 Answers

Jesse Walters
Jesse Walters

Level 2 Expert

337 Answers

Are you a Maytag Refrigerator Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...